47
HNC3 825 / HNC3 825 perform
Setup and installation
1
2
Fig. 28: Connect frequency converter HNC3 825 perform
1 Mains connection C14
2 Main switch
NOTICE
Incorrect mains frequency
Damage to the HF spindle
−
The HF spindle must always have a 230 volt supply. If neces-
sary, a frequency converter must be used.
1.
Place the frequency inverter on a flat, stable surface, next to the machine.
2.
Compare the information on the nameplate with that of the power supply.
Only connect the machine if the two sets of data correspond to each other.
3.
Connect the machine using the C13 plug at the rear of the machine to the
power supply.
Emergency stop button
1
Fig. 29: Connection emergency stop
1 Connection emergency stop
1.
Switch off the machine at the main switch, disconnect the power supply.
2.
Connect the emergency stop button to the emergency stop connection.