83
A2-26
Troubleshooting
1
2
3
4
Fig. 61: System Planer Knife
1 Blade-holder screws
2 Blade holder
3 Planer Knives
4 Allen Key
Protective equipment:
●
Protective clothing
●
Protective gloves
Tool:
●
Cleaning cloths
●
Resin remover
●
Vacuum cleaner
●
Hex key
●
System Planer Knife HS-M42
●
Standard system planer knife
1.
Switch off the machine and secure it against being switched on again.
2.
Disconnect the machine from the mains power supply.
Change the machine over for thickness planing, swing the extraction hood
up.
Chapter 8.1.6 ‘Changing over from a planer to a thicknesser’
3.
Release all the blade holder screws of a blade and remove the blade holder
and planer blades. Release all the blade holder screws of a blade and
remove the blade holder and planer blades. Repeat this process with all
blades.
4.
Clean the planer blades, blade holders and cutterblock of traces of resin as
thoroughly as possible.
5.
Reverse the planer knife (if only one cutting edge is worn).
6.
Reinsert the planer blades and blade holders, tighten the blade holder
screws lightly at first, then firmly.
Ensure correct installation position of the planing knives (direction of rotation
of the cutterblock).
7.
Always tighten the knife holder screws from the inside outwards.
Minimum tightening torque: 20 Nm