Document #101-0086
66
5/22/07
To stop accepting all Tokenotes® already programmed into the validator.
(This erases any record that the Tokenotes® were ever programmed)
PROGRAMMING THE STA VALIDATOR:
1.
With the power on, check the operation of the validator. A dot flashing
on the LED indicates it is operating normally.
2.
Note the position of each switch on the DIP switch. (The DIP switch is
located on the side of the validator.)
3.
Set all 8 DIP switches to the OFF position. Then, starting with switch
#8, slowly move the switches to the ON position, one switch at a time
and in descending order (8, 7, 6, 5…). The LED should now be flash-
ing the letter “P”. This signifies that the validator is in the Tokenote®
Programming Mode.
4.
Insert the CLEAR ALL Training Coupon into the validator, making
sure that it is accepted.
5.
Starting with switch #1, slowly move the switches back to their origi-
nal positions one at a time. This must be done in ascending order (1, 2,
3, 4…). A dot should now be flashing on the LED.
PROGRAMMING THE HVX or XE VALIDATOR:
1.
With the power on, check the operation of the validator. A dot flashing
on the LED indicates it is operating normally.
2.
Note the position of each switch on the DIP switch. (The DIP switch is
located on the side of the validator.)
3.
Set all 10 DIP switches to the OFF position. Then, starting with switch
#10, slowly move the switches to the ON position, one switch at a time
and in descending order (10, 9, 8, 7…). The LED should now be
flashing the letter “P”. This signifies that the validator is in the To-
kenote® Programming Mode.
4.
Insert the CLEAR ALL Training Coupon into the validator, making
sure that it is accepted.
5.
Starting with switch #1, slowly move the switches back to their origi-
nal positions one at a time. This must be done in ascending order (1, 2,
3, 4…). A dot should now be flashing on the LED.