The OUT-OF-SERVICE RELAY is included in the GL-ACW-P. Terminals B3 (normally
open), B4 (common) and B5 (normally closed) are supplied as well. If an error occurs that
causes the GL-ACW-P to go out of service, the relay will be activated.
Additional Wire Terminations For Use With The Credit
Card System
The installation of the machine should proceed as outlined in the above section. However, if a Credit
Card System is being used, the following must be performed, as well.
•
The telephone line used for the ACW must be a dedicated line. No
other telephones or equipment can be connected with the same line.
(The use of line splitters is not permitted.) If more than one machine
is to be installed at the same location, a dedicated phone line must be
run to each machine.
•
The telephone line should be run in a separate conduit. If any other
wiring is run in the same conduit, communication problems could
occur.
Setting Cycle Synchronization Switch
The Cycle Synchronization Switch is the silver toggle switch located on the Relay Panel. If an external
signal is being used to inhibit the operation of the GL-ACW-P this switch determines how the Cycle/
Inhibit relay should operate. In the (A) active mode external power must be supplied to the coil of the
relay during normal operation then removed to inhibit the GL-ACW-P. In the (P) passive mode no
external power is supplied to the coil of the relay during normal operation. The coil would be energized
to inhibit the GL-ACW-P. When not using an external inhibit signal this switch should be set to the (P)
passive mode.
General Test
After completing all of the steps under Mechanical and Electrical Installation, be sure to test the
following items for proper function.
•
Turn on power at the Relay Panel.
•
Be sure to test all facets of the operation, including the bill acceptor
and coin acceptors.
•
Test for proper actuation of gate and Cycle/Inhibit control.
•
Ensure that coins are being dispensed for both change and as a refund.
If there are any problems refer to the TROUBLESHOOTING section
or contact Hamilton Mfg.