background image

2

SmartServe™ Safety

IMPORTANT SAFETY INSTRUCTIONS

When using electrical equipment, basic safety precautions should be followed to reduce the risk of personal injury, 

including the following:

– SAVE THESE IN STRUC TIONS –

1.  Read all instructions.

2.  This appliance is not intended for use by persons 

with reduced physical, sensory, or mental 

capabilities, or lack of experience and knowledge, 

unless they are closely supervised and instructed 

concerning use of the appliance by a person 

responsible for their safety.

3.  This appliance shall not be used by children. Keep 

the appliance and its cord out of reach of children.

4.  Close supervision is necessary when any appliance 

is used near children. Children should be supervised 

to ensure that they do not play with the appliance.

5.  Plug into a grounded 3-prong outlet.

6.  Do not remove ground prong.

7.  Do not use an adapter.

8.  Do not use an extension cord.

9.  Disconnect power before cleaning or servicing, and 

before installing or removing agitator.

10. To protect against electric shock, do not spray 

equipment with a high-pressure spray gun or 

immerse the cord, plug, or equipment in water.

11. Do not operate any appliance with a damaged supply 

cord or plug, or after the appliance malfunctions 

or has been dropped or damaged in any manner. 

Supply cord replacement and repairs must be 

conducted by the manufacturer, its service agent, or 

similarly qualified persons in order to avoid a hazard. 

Call the provided customer service number for 

information on examination, repair, or adjustment.

12. To reduce risk of personal injury and to prevent 

damage to the equipment, DO NOT insert utensils 

into equipment while operating.

13. Do not use the equipment for other than intended 

use.

14. The use of accessory attachments not recommended 

by Hamilton Beach may cause injuries.

15. Blades are sharp. Handle carefully.

16. Do not use broken, loose, or cracked cutting blades.

17. Do not use outdoors.

18. Equipment must be mounted to the supporting 

surface according to instructions. 

NOTE: The supply water must be maintained between 

40 psi (2.76 bar) MINIMUM and 80 psi  

(5.52 bar) MAXIMUM and should be regulated to a set 

point within ± 5 psi (± 0.345 bar). This will promote 

proper and consistent rinse performance on BIC 

models and will also maintain consistent water input 

calibration on the MIC models. Lower than acceptable 

water pressure may result in incomplete rinse functions. 

Higher than acceptable water pressure could cause 

premature failure of system components

.

Technical Services

For assistance or replacement parts, call or email 

Technical Services: 

866-285-1087 (USA, Canada) or +1-910-693-4277 

[email protected]

APAC Region: +86-400-930-2722,  

[email protected] 

www.hamiltonbeachcommercial.com

For Commercial Use Only

Your safety and the safety of oth ers is very important.

We have provided many important safety messages in this manual and on your machine. Always read and 

obey all safety messages.

This is the safety alert symbol.
This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “WARNING.” 

This word means:

w

WARNING

You may be killed or seriously injured if you don't 

follow instructions.

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what 

can happen if the instructions are not followed.

IMPORTANT: This operation manual should be reviewed with all equipment operators as part of your 

operator training program.

Summary of Contents for SmartServe

Page 1: ...nual Page 2 SmartServe Manuel d utilisation Page 11 SmartServe Manual de operaci n Page 19 READ BEFORE USE LIRE AVANT D UTILISER LEA ANTES DE USAR For more visit www hamiltonbeachcommercial com Good T...

Page 2: ...not use the equipment for other than intended use 14 The use of accessory attachments not recommended by Hamilton Beach may cause injuries 15 Blades are sharp Handle carefully 16 Do not use broken lo...

Page 3: ...screws 2 NOTE Cup holder may look different depending on model purchased USB Port Door Assembly Wash Chamber Drain Removable Splash Shield Cup Guard Assembly Cup Guard Blending Blade depending on mode...

Page 4: ...nstructions below for securing to countertop with bolts washers and nuts 3 Attach a standard 1 4 OD semi rigid water line for rinsing 4 Insert drain connection using supplied Black Drain Pipe or stand...

Page 5: ...Port 2 Turn Power Switch to the ON I position 3 Follow instructions on display to allow file to download completely 4 Turn Power Switch to the OFF position 5 Remove flash drive 6 Turn Power Switch to...

Page 6: ...ighest position 6 After appropriate sanitizer time remove cup and pour contents down the drain 7 Allow the equipment to rinse For MIC only Press the RINSE button NOTE If this is done at end of day tur...

Page 7: ...cycle This feature can be disabled if preferred by pressing START and the machine can be manually operated by pressing RINSE on the control panel CUP SENSOR Your SmartServe may be fitted with a Cup S...

Page 8: ...h Shield rest in the Wash Chamber 8 Lift the Cup Guard Assembly upwards approximately 3 76 cm to allow room to remove the Splash Shield 9 Wipe the Wash Chamber Cup Guard and upper part of Cup Guard As...

Page 9: ...the unit shows a part needs to be replaced Contact your local service representative parts distributor or call our Technical Services team to receive assistance The seal above the Motor Shaft is leaki...

Page 10: ...10 Notes...

Page 11: ...s pr vues 14 L utilisation d accessoires non recommand s par Hamilton Beach peuvent provoquer des blessures 15 Les lames sont coupantes Les manipuler avec prudence 16 Ne pas utiliser des lames bris es...

Page 12: ...rent selon le mod le achet Port USB Ensemble de porte Compartiment de lavage drain Couvercle anti claboussures amovible Ensemble de protecteur de r cipient Protecteur de r cipient Lame m langeuse selo...

Page 13: ...rondelles et crous 3 Ins rer une conduit d eau semi rigide classique de 6 3 mm 1 4 po D E 4 Ins rer le raccord de drain en utilisant le tuyau de drainage noir fourni ou un tuyau de PVC de 19 0 mm 3 4...

Page 14: ...upteur la position ON I marche pour mettre sous tension 3 Suivre les instructions sur l afficheur et attendre la fin du t l chargement du fichier 4 Mettre l interrupteur la position OFF arr t pour met...

Page 15: ...ntenu dans le drain 7 Permettre le rin age de l appareil Pour MIC seulement Appuyer sur le bouton RINSE rin age REMARQUE Si la d sinfection est faite en fin de journ e mettre l appareil hors tension O...

Page 16: ...n Cette caract ristique peut tre d sactiv e en appuyant sur START d marrer pour que la mise en marche de l appareil se fasse manuellement en appuyant sur le bouton RINSE rin age du panneau de commande...

Page 17: ...cher 8 Soulever l ensemble du protecteur de r cipient sur environ 76 cm 3 po pour d gager un espace afin de retirer le couvercle anti claboussures 9 Essuyer le compartiment de lavage le couvercle du...

Page 18: ...le bon programme a t t l charg L afficheur de l appareil indique qu une pi ce doit tre remplac e Communiquer avec le vendeur local le distributeur de pi ces ou les Services techniques pour obtenir de...

Page 19: ...lios dentro del artefacto durante su funcionamiento 14 S lo utilice el aparato con el objetivo para el que fue dise ado 15 El uso de accesorios no recomendados por Hamilton Beach puede provocar lesion...

Page 20: ...o del modelo adquirido Puerto USB Montaje de la puerta C mara de lavado drenaje Protecci n contra salpicaduras desmontable Montaje de protecci n de la taza Protecci n de la taza Cuchilla para licuar d...

Page 21: ...siguientes para anclar la unidad al mostrador con pernos arandelas y tuercas 3 Instale una l nea de agua est ndar semi r gida de 1 4 de DE para el enjuague 4 Introduzca la conexi n de drenaje utilizan...

Page 22: ...ciones de la pantalla para que el archivo se descargue por completo 4 Coloque el interruptor de energ a en la posici n de OFF apagado 5 Quite la memoria flash 6 Coloque el interruptor de energ a en la...

Page 23: ...el tiempo de desinfecci n apropiado quite la taza y vierta el contenido en el desag e 7 Deje que la m quina se enjuague S lo para MIC Presione el bot n RINSE enjuague NOTA Si esto se realiza al final...

Page 24: ...desea esta caracter stica puede desactivarse presionando START iniciar y la m quina puede operarse en forma manual presionando RINSE enjuague en el panel de control CUP SENSOR SENSOR DE TAZA Su SmartS...

Page 25: ...lavado 8 Levante el montaje de la protecci n de la taza hacia arriba aproximadamente 3 76 cm para dejar espacio para retirar la protecci n contra salpicaduras 9 Limpie la c mara de lavado la tapa de l...

Page 26: ...ala que debe reemplazarse una pieza Comun quese con su representante local de servicio t cnico distribuidor de piezas o llame a nuestro equipo de Servicios T cnicos para obtener ayuda El sellado ubica...

Page 27: ...27 Notas...

Page 28: ...as BIC2000 BIC2100 MIC2000 GM43 120 V 60 Hz 3 0 A Los modelos inclu dos en el instructivo de Uso y Cuidado pueden ir seguidos o no por un sufijo correspondiente a una o varias letras del alfabeto y su...

Reviews: