background image

5

1/3

2/3

1/3

2/3

Attachments

Illuminated Variable Speed Dial

No light

Unit is turned OFF ( ). 

1

Flashing Green Unit is ready to turn ON (blend).

2

Solid Purple

Unit is ready to blend.

3

Solid Blue

Unit is blending.

4

Flashing Blue 

Unit is blending in continuous run 

mode.

5

Flashing 

Yellow

Unit is starting to overheat. See 

“Troubleshooting” section.

6

Flashing Red

Error, see “Troubleshooting” section

Attachment

Length

Recommended Standard 

Capacity

Uses

Whisk

10” (254 mm)

Up to 4 gal (16 qts [15 L])

Batter, mayonnaise, egg 

whites, pudding, mousse, 

whipped cream

Stainless 

Steel Blending 

Attachment

12” (305 mm)
14” (355 mm)
16” (406 mm)
18” (457 mm)
21” (533 mm)

Up to 6 gal (24 qts [23 L])
Up to 14 gal (56 qts [53 L])
Up to 23 gal (92 qts [87 L])
Up to 32 gal (128 qts [121 L])
Up to 42 gal (168 qts [156 L])

Soups, purees, compotes, 

sauces, bisques, cooked 

meats, gravy, liquefied 

fruits, minces

If the Immersion Blender will not be used again within one hour, sanitize in the following manner:
1.  Wash as instructed. (

)

2.  Following general cleaning, immerse attachment in a container of a cold, chlorine-based sanitizing solution that has a 

minimum chlorine concentration of 100 parts per million for one minute. See recommended solution below. 

3.  Do not rinse. Allow attachment to air-dry before use.

Recommended Sanitizing Solution:

The sanitizing solution should consist of one tablespoon (14.8 ml) of household bleach per one gallon (3.8 L) of 

clean, cool water (minimum 75ºF [24ºC] – 120ºF [49ºC]) mixed according to the instructions on the bleach. When 

using a sanitizing solution other than that recommended, the sanitizing solution concentration should be tested using 

commercially available test strips and should indicate a chlorine concentration between 100 and 200 parts per million.

Sanitizing Instructions

Ways to Hold the Immersion Blender

Icons

Functions
Momentary Run: Blender motor 

will turn off when you remove 

finger from Start/Stop Trigger.
Continuous Run: Blender motor 

locks in ON position. Turn motor 

off by pressing Power Switch or 

Interlock/Continuous Run Button. 

OR

OR

X

Summary of Contents for HMI Series

Page 1: ...ial com FOR COMMERCIAL USE ONLY HMI Series IMMERSION BLENDER Operation Manual Page 2 M LANGEUR MAIN Manuel d utilisation Page 7 BATIDORA DE BRAZO Manual de operaci n P gina 12 Le invitamos a leer cuid...

Page 2: ...alified persons in order to avoid a hazard Call the provided customer service number for information on examination repair or adjustment 10 The use of attachments not recommended or sold by Hamilton B...

Page 3: ...s cuts or other serious injuries w WARNING Electrical Shock Hazard Do not use an extension cord Do not put motor housing cord or plug in water or any other liquid Failure to follow these instructions...

Page 4: ...Stop STOP Trigger Interlock Continuous Run Button Power Switch Cord 10 254 mm Whisk Attachment 12 305 mm Stainless Steel Blending Attachment 14 355 mm Stainless Steel Blending Attachment 16 406 mm Sta...

Page 5: ...tize in the following manner 1 Wash as instructed 2 Following general cleaning immerse attachment in a container of a cold chlorine based sanitizing solution that has a minimum chlorine concentration...

Page 6: ...rotating Three flashes Motor speed too fast overshoot Unplug from outlet and wait 30 seconds Plug Immersion Blender into outlet and continue to use If error continues call customer support Immersion...

Page 7: ...ncernant l examen la r paration ou l ajustement 10 L utilisation d accessoires non recommand s ou vendus par Hamilton Beach peut entra ner un risque d incendie de choc lectrique et de blessures corpor...

Page 8: ...ctions peut entra ner des fractures des coupures ou autres blessures graves w AVERTISSEMENT Risques de choc lectrique Ne pas utiliser de rallonge lectrique Ne pas immerger le bloc moteur le cordon d a...

Page 9: ...21 po ACCESSOIRES FACULTATIFS Pince de rangement pour cordon d alimentation Manche Prise Accessoire pour m langer en acier inoxydable Prot ge lame Lame prot ge lame int rieur Patte murale n inclut pas...

Page 10: ...ives 2 Apr s le nettoyage g n ral immerger l accessoire dans un r cipient contenant une solution d sinfectante froide base de chlore dont la concentration en chlore est d un minimum de 100 parties par...

Page 11: ...0 secondes Brancher le m langeur main dans la prise et poursuivre l utilisation Si l erreur persiste veuillez communiquer avec le service la client le Le m langeur main ne se met pas en marche Veuille...

Page 12: ...sonas igualmente calificadas para poder evitar un peligro Llame al n mero de servicio al cliente proporcionado para informaci n sobre examinaci n reparaci n o ajuste 11 El uso de accesorios que no hay...

Page 13: ...rovocar fractura de huesos cortadas u otras lesiones w ADVERTENCIA Riesgo de descarga el ctrica No utilice un cable de extensi n No coloque la carcasa del motor el cable o el enchufe en agua o cualqui...

Page 14: ...ip para almacenamiento del cable Empu adura principal Sujetador Accesorio para batir extra ble de acero inoxidable Protector de la cuchilla Cuchilla guarda para cuchilla interior Gancho de pared no in...

Page 15: ...a higienice de la siguiente manera 1 Lave seg n las instrucciones 2 Despu s de la limpieza general sumerja el accesorio en un recipiente con una soluci n desinfectante fr a a base de cloro que tenga u...

Page 16: ...siado r pida sobreimpulso Desconecte del tomacorriente y espere 30 segundos Enchufe la batidora de brazo en el tomacorriente y contin e us ndola Si la falla contin a llame al servicio de atenci n al c...

Page 17: ...17 STOP 2s STOP 1 2 4 6 7 6 7 8 2 1 3 3 4 1 2 3 3 4 1 1 5 3 X...

Page 18: ...18 STOP 7 4 5 2 1 3 3 6 2 8 9 10 11 12 1 3 3 1 X...

Page 19: ...19 110 F 43 C 110 F 43 C 2 1 30s STOP 3 1 2 3 4 5 6 7 8 9 10 11 12 13 3 1 14 X...

Page 20: ...20 110 F 43 C 1 30s STOP 3 1 2 3 4 5 6 7 8 9 10 11 12 3 1 2 X 110 F 43 C 13 14 15 16...

Page 21: ...21 Notes Remarques Notas...

Page 22: ...22 Notes Remarques Notas...

Page 23: ...n sufijo correspondiente a una o varias letras del alfabeto y sus combinaciones separadas o no por un espacio coma diagonal o gui n Como ejemplos los sufijos pueden ser Y y o MX y o MXY y o Z Modelos...

Page 24: ...4421 Waterfront Drive Glen Allen VA 23060 840319201 07 20 www hamiltonbeachcommercial com...