8
Subject to change without notice
F r o n t P a n e l E l e m e n t s – B r i e f D e s c r i p t i o n
Front Panel Elements – Brief Description
1
POWER
(pushbutton)
26
Turns scope on and off.
2
INTENS
(knob)
26
Intensity for trace and readout brightness, focus and trace
rotation control.
3
FOCUS, TRACE, MENU
(pushbutton)
26
Calls the Intensity Knob menu to be displayed and enables
the change of different settings using the INTENS knob. See
item 2.
4
CURSOR MEASURE
(pushbutton)
27
Calls the ”Cursor” menu and offers measurement selection
and activation.
5
ANALOG/DIGITAL
(pushbutton)
27
Switches between analog (green) and digital mode (blue).
6
STOP / RUN
(pushbutton)
28
RUN: Signal data acquisition enabled.
STOP (constantly lit): Signal data acquisition is stopped
STOP
(fl ashing): Signal data acquisition is in progress and
and fl ashing stops when completed.
7
MATH
(pushbutton)
28
Calls mathematical function menu if digital mode is pre-
sent.
8
ACQUIRE
(pushbutton)
29
Calls the signal capture and display mode menu in digital
mode.
9
SAVE/RECALL
(pushbutton)
30
Offers access to the reference signal (digital mode only) and
the instrument settings memory.
10
SETTINGS
(pushbutton)
31
Opens menu for language and miscellaneous functions; in
digital mode also signal display mode.
11
AUTOSET
(pushbutton)
32
Enables appropriate, signal related, automatic instrument
settings.
12
HELP
(pushbutton)
32
Switches help texts regarding controls and menus on and
off.
13
POSITION 1
(knob)
32
Controls position of actual present functions: Signal (current,
reference or mathematics), Cursor and ZOOM (digital).
14
POSITION 2
(knob)
33
Controls position of actual present functions: Signal (current,
reference or mathematics) Cursor and ZOOM (digital).
15
CH1/2-CURSOR-MA/REF-ZOOM
(pushbutton)
34
Calls the menu and indicates the current function of POSI-
TION 1 and 2 controls.
16
VOLTS/DIV-SCALE-VAR
(knob)
34
Channel 1 Y defl ection coeffi cient, Y variabel and Y scaling
setting.
17
VOLTS/DIV-SCALE-VAR
(knob)
34
Channel 2 Y defl ection coeffi cient, Y variabel and Y scaling
setting.
18
AUTO MEASURE
(pushbutton)
35
Calls menus and submenus for automatic measurement.
19
LEVEL A/B - FFT-Marker
(knob)
36
Trigger level control for A and B Time Base. Marker position
shift in FFT mode.
20
MODE
(pushbutton)
36
Calls selectable trigger modes.
21
FILTER
(pushbutton)
36
Calls menu for trigger fi lter (coupling), noise reject and slope
selection.
22
SOURCE
(pushbutton)
37
Calls trigger source menu (e.g. CH1, CH2, Alt. 1/2, External,
AC Line).
23
TRIG’d
(LED)
38
Lit when the trigger signal meets the trigger conditions.
24
NORM
(LED)
38
Lit if NORMAL or SINGLE event triggering is chosen.
25
HOLD OFF
(LED)
38
Lit if a hold off time is set (only in analog mode)
>
0% in the
HOR menu (HOR VAR pushbutton
30
).
26
X-POS / DELAY
(pushbutton)
38
Calls and indicates (colour) the actual function of the HO-
RIZONTAL knob
27
, (X-POS dark).
27
HORIZONTAL
(knob)
39
Changes the X position or in digital mode, the delay time
(Pre- or Post-Trigger). In FFT mode for center frequency
control.
28
TIME/DIV-SCALE-VAR
(knob) 39
Setting of A and B time base (defl ection coeffi cient), time
fi ne control (VAR; only in analog mode) and scaling; Span
in FFT mode.
29
MAG x10
(pushbutton)
40
10 fold expansion in X direction in analog Yt mode, with
simultaneous change of the defl ection coeffi cient display
in the readout.
30
HOR / VAR
(pushbutton)
40
Calls ZOOM function (digital); in analog mode time base A
and B, time base variable and hold off control.
31
CH1 / VAR
(pushbutton)
42
Calls channel 1 menu with input coupling (AC, DC, GND),
inverting, probe and Y variable control.
32
VERT/XY
(pushbutton)
43
Calls vertical mode selection, addition, XY mode and band-
width limiter.
33
CH2 / VAR
(pushbutton)
44
Calls channel 2 menu with input coupling (AC, DC, GND),
inverting, probe and Y variable control.
The fi gures indicate the page for complete discription
in the chapter CONTROLS AND READOUT
▼