25
Avg. Mode
•
Normal Running Average of
n
Samples (Default)
•
Reset Average if Position Change Exceeds STDEV (Standard Deviation)
•
Reset Average if Position Change Exceeds 2*STDEV (2X Standard Deviation)
•
Reset Average if Position Change Exceeds 4*STDEV (4X Standard Deviation)
•
Reset Average if Position Change Exceeds 8*STDEV (8X Standard Deviation)
•
Reset Average if Position Change Exceeds 4
μm (4 M
icrons)
•
Reset Average if Position Change Exceeds 8 μm (8 Microns)
•
Reset Average if Position Change Exceeds 16 μm (16 Microns)
•
Reset Average if Position Change Exceeds 32 μm (32 Microns)
•
Reset Average if Position Change Exceeds 64 μm (64 Microns)
Note:
Reset Position Modes should be used only for very stable environments.
Pos. Sensing
The Unitarget utility is
not
compatible with the Type I (IR or radio) Unitargets. The utility is only
intended for use with Type II A-1519 and A-1520 Unitargets. The Type II Unitargets have a USB and an
AUX port on the left side of the target and a circular connector in the back. The Type I Unitarget is
smaller and only has a single circular connector in the back.
There are two types of Type II Unitargets in the field. The A-1519 targets can be identified by the sensor
type, visible through the front window as shown
Type II-Legacy, Single Axis Sensor
•
Compatible with radio version of the
Type I Unitarget.
•
Supports all scanning lasers.
•
Does
not
support fixed (continuous) or
pulsed line lasers.
Type II-Current Version, Dual Axis Sensor
•
Supports all scanning lasers.
•
Supports fixed (continuous) and pulsed
line lasers.
Configure the target using the utility, based on
the laser type and Type II Unitarget as follows:
Scanning, Single Axis Legacy Mode:
Select
this mode for Type II Legacy Targets
only
. Select
for use with scanning lasers only.
Scanning, Dual Axis Mode:
Select this mode
for Type II, current version. Select for use with
scanning lasers only.
Fixed Beam, Dual Axis:
Select this mode for all continuous line lasers (for example the L-700 and L-
705 in continuous mode).
Pulsed Beam, Dual Axis:
Select this mode for use with pulsed line lasers only (for example, the L-705
in pulsed beam mode).
Figure 44 –
A-1519 Single and Dual-Axis Sensors