13
Installation of the HR 1000 RVS micro cleaner
For installation follow the following procedure:
Remove the carton box – one person can relocate the micro cleaner upright to the assigned
area which must be well ventilated and away from electrical switches, sources of heat and
sparks.
Earth the installation by leading the bi-coloured cable from the mounting bolt near the air
supply connection to the ground.
The micro cleaner is developed for wall attachment and before positioning,
mark the position of the holes to be bored in the wall. Hang the micro cleaner with the help of
screws and plugs and check if it is level and firmly fixed.
Connect the outlet tap on the right hand bottom side: this is for draining polluted cleaning
agent.
Connect the air coupling on the left hand bottom side.
Install a fixed or flexible pipe line to the vapour outlet aligned vertically for 80 – 100 cm. and
lead this outdoors. If the chimney is longer than 2 metres, use a galvanised iron exhaust pipe
with a diameter of 15 cm.
to prevent friction and place the bend as far away as possible from the micro cleaner. E.g. if
the exhaust pipe is 5 metre long, lead it for 3-4 metres vertically and 1-2 metres horizontally
instead of 1 metre vertically and 4 metres horizontally. Close the cover plate.
Check if the outlet tap is closed.
Operating procedure
Fix an air hose to the air connector on the bottom left hand side with quick connector. Open the cover plate
: the air extraction now automatically functions. A safety ratchet gear on the left side of the cover causes
the venturi system to start up when opening the cover and directly stops when closing it. If this functions
well, pour a minimum of 3 lit. (max. 7 lit.) cleaning agent into the tank and replace the receptacle plate to
the tank.
Turn on the tap on the left side: now solvent is fed via the hose to the brush. If this functions well, the
micro cleaner is ready for use. Fill the rest of the tank with cleaning agent (a total of max. 7 lit. ) and close
the cover plate.
When the cover is closed the venturi extraction will not function.
Concluding the cleaning process
When you have finished cleaning small parts and putty, close the cover.
Draining polluted solvent
Close the cover and hold a jerry can (min.10 litre capacity ) under the tap.
Turn the tap open. The polluted cleaning agent is now discharged from the tank into the jerry can. Close the
tap. Remove the receptacle from the tank and pour ½ litre clean solvent into the tank. Clean the tank and
the filter which is attached to the suction hose. Hold the jerry can under the drain tap, turn the tap on and
clean the tank with the brush. Close the tap. Again fill the tank with clean solvent: the micro cleaner is now
ready for re-use.
Insufficient vapour extraction
Check if the feed air pressure is at least 3 bar.
Check if the outlet pipe is positioned perfectly vertical for at least 1 metre.
If the extraction is faulty, make your own initial inspection before calling in your supplier/EMM.