10
SAFETY
It is essential that these instructions are strictly followed for the safe
and economical operation of this appliance.
The appliance is a fan-assisted balanced flue gas boiler and
therefore the flue terminal
MUST NOT BE OBSTRUCTED
under
any circumstances. If it is damaged, turn off the appliance and
consult your installer, service engineer, or BG Service.
If it is known or suspected that a fault exists on the appliance it
MUST NOT
be used until the fault has been rectified by a
competent person.
9
CLEANING
Use only a damp cloth and mild detergent to clean the appliance
outer casing.
DO NOT
use abrasive cleaners.
8.3
C.H. WATER FLOW SWITCH
This device prevents the burner from igniting if there is inadequate
water flow through the main heat exchanger. If the Power On LED
flashes, this indicates failure of the flow switch and your installer
or service engineer should be contacted.
8.2
ANTI PUMP SEIZURE DEVICE
Providing that a power supply is maintained, The pump will
operate for at least 20 seconds every 23 hours (regardless of heat
demand) to prevent pump seizure during periods when the
appliance is not used.
8
OTHER FEATURES
The following additional features are included in the
appliance specification:
8.1
ANTI-CYCLE DEVICE
When the appliance cycles on it’s central heating control setting, a
slow cycle device operates. This allows the water to heat up
slowly thus preventing rapid cycling of the burners.
Summary of Contents for Ace High
Page 8: ...8 EXPLODED DIAGRAM for key no references see spare parts catalogue Drawing amended 8 6 00 6 ...
Page 25: ...INTERNAL WIRING DIAGRAMS 7 7 1 FUNCTIONAL FLOW WIRING DIAGRAM 23 ...
Page 26: ...7 2 ILLUSTRATED WIRING DIAGRAM 24 ...
Page 40: ...Ace Ace High Wickes Combi 82 102 05 04 ACE ACE HIGH WICKES COMBI 82 102 ...