ELECTRICAL CONNECTIONS
(rear view)
27
INSTALLING THE FLUE SYSTEM FROM OUTSIDE THE BUILDING
4.8
WIRING INSTRUCTIONS
Connect the electricy supply and external controls (using suitable
mains cable) as follows:
Wire the cable(s) into the appropriate connections in the electrical
plug provided (Figure 28). Live supply to L2, Neutral and Earth as
indicated. Check that L1 and L3 are linked.
To provide correct cable retention, fit the piece of tubing supplied
over the cable as it passes through the clamping arrangement. The
cable will be held in position as the plug cover is fitted.
If a room thermostat is to be fitted remove the red link between L1
and L3 and connect the thermostat across these terminals. Any
external controls fitted must be rated at 230V 50Hz and have volt-
free contacts.
NOTE: Assuming that the appliance is to be
commissioned immediately after installation it is not
necessary to fit the casing panels at this stage.
•
•
•
•
•
4
REFIT AND SECURE
ELBOW TO AIR DUCT,
THEN TO APPLIANCE
1
FIT ELBOW
(AFTER SETTING CORRECT
LENGTH AND ALIGNMENT)
3
SLIDE INTERNAL
WALL SEALING RING
OVER AIRDUCT. PUSH
AGAINST THE WALL TO
FORM A GOOD SEAL
2
INSERT FLUE
LENGTHS FROM
OUTSIDE THE
ROOM. ENSURE
EXTERNAL WALL
SEALING RING
FORMS A GOOD
SEAL
•
EXTERNAL
WALL
SEALING
RING
TOP
100mm
Dia. HOLE
INTERNAL WALL
SEALING RING
•
FIBRE SEAL FITTED
(Flue hole diameter 100mm - wall liner not necessary)
a)
Secure the flue elbow with seals and flue adaptor (where
necessary) to the appliance using the 4 screws provided.
b)
Fit external wall sealing ring over flue and then from outside
the building, push the flue system through the wall taking care
to ensure that the terminal is the correct way around.
c)
Fit the internal wall sealing ring over the inside end of the flue,
then fit the air duct to the elbow, drill and secure with the two
screws.
d)
Pull the flue system towards the boiler to seat the external
sealing ring against the outside wall and secure the air duct to
the elbow using the two screws provided.
e)
Finally use the internal sealing ring to make good the internal
hole. Check that the external wall sealing ring is correctly
located, on the outside wall from outside the building.
Figure 27 shows a view of the flue system, correctly installed.
4.7.4
INSTALLING THE AIR/FLUE DUCT
FROM OUTSIDE THE BUILDING
17
Note: If room thermostat is to
be fitted remove the link and
connect room thermostat
across L1 and L3.
Summary of Contents for Ace High
Page 8: ...8 EXPLODED DIAGRAM for key no references see spare parts catalogue Drawing amended 8 6 00 6 ...
Page 25: ...INTERNAL WIRING DIAGRAMS 7 7 1 FUNCTIONAL FLOW WIRING DIAGRAM 23 ...
Page 26: ...7 2 ILLUSTRATED WIRING DIAGRAM 24 ...
Page 40: ...Ace Ace High Wickes Combi 82 102 05 04 ACE ACE HIGH WICKES COMBI 82 102 ...