FLUE SYSTEM ASSEMBLY
AND DIMENSIONS
••
•
•
•
•
•
•
•
•
180mm
430mm
1045mm max
30mm
767mm
767mm
767mm
425mm
50mm
ACE = 4618 (4 extensions)
BALANCED FLUE
ROOF TERMINAL
•
ROOF LINE
•
100/60mm TO
118/80mm DIA
ADAPTOR
•
100/60mm DIA
EXTENSION DUCT
•
STANDARD DUCT OUTER
SECTION TELESCOPIC
•
100/60mm DIA
EXTENSION DUCT
•
100/60mm DIA
EXTENSION DUCT
•
•
VERTICAL
SOCKET
•
•
•
•
•
SUPPLEMENT
11
Supplementary instructions for flue systems with a vertical outlet.
a)
Read the installation requirements and flue specifications
described in section 3.
b)
Follow the installation procedure described in section 4 up to
section 4.7 (but making the necessary hole(s) in the ceiling/roof
instead of the wall). Use the following instructions in place of
section 4.7.
c)
Measure the vertical distance from the top of the boiler case to
the roof line (Fig. 39). Use this length to calculate the number of
extension ducts required.
d)
Starting at the boiler, fit the vertical socket, standard duct and
extensions required. Then fit the adaptors. Ensure that they are in
line (level).
e)
Now working from outside fit the balanced flue roof terminal,
ensuring the roof flashing and sealing components are secured to
the roof.
f)
Ensure the inner and outer ducts are correctly fitted to the
adaptor.
Note: All the joints should be secured using the self-tapping screws supplied.
Summary of Contents for Ace High
Page 8: ...8 EXPLODED DIAGRAM for key no references see spare parts catalogue Drawing amended 8 6 00 6 ...
Page 25: ...INTERNAL WIRING DIAGRAMS 7 7 1 FUNCTIONAL FLOW WIRING DIAGRAM 23 ...
Page 26: ...7 2 ILLUSTRATED WIRING DIAGRAM 24 ...
Page 40: ...Ace Ace High Wickes Combi 82 102 05 04 ACE ACE HIGH WICKES COMBI 82 102 ...