Central
Heating
DHW
Max. gas rate (after 10 mins operation i.e. hot)
2.81 m
3
/h (100
ft
3
/h)
Factory set gas rate (after 10 min operation)
2.0 m3/h
(71 ft3/h)
Min. domestic hot water flow rate
2.8 l/min
(0.6 gpm)
Design domestic hot water performance
9.8/min (2.1 gpm) raised 35°C
Max. domestic hot water temperature
73+/-2°C
Max. mains water inlet pressure
10 bar
(146 psi)
Min. mains water inlet pressure for operation
0.3 bar
(4.4 psi)
Min. mains water inlet pressure for max heat output
1.0 bar
(14.6 psi)
Max gas rate (after 10 mins operation, i.e. hot)
2.81 m3/h
(100 ft3/h)
1
TECHNICAL SPECIFICATIONS
2
HALSTEAD ACE
HALSTEAD ACE HIGH
2.2
PERFORMANCE DATA
1
.
.
.
.
.
.
.
.
.
.
.
.
.
100mm DIA.
325mm
188mm
225mm
760mm
455mm
900mm
95mm
.
.
.
1(a)
200mm
5mm
200mm
5mm
SEE
NOTE
••
•
•
•
•
•
•
••
The appliances are Certified to comply with the requirements of
EN 483 and EN 625 for use in GB and IE (Great Britain and
Ireland) using the following gas categories:
Ace/Ace High: I
2H
(G20 with a governed gas supply at 20 mbar
(8 in.wg) inlet pressure)
The appliance classification (as defined in EN 483) may be any of the
following depending on the chosen flue option: C12 or C32.
2.1
GAS CATEGORIES AND
APPLIANCE CLASSIFICATION
2.3
MINIMUM CLEARANCES
Main burner injector
ø 1.30 mm x 13
Total water capacity
1 litre
Minimum CH system pressure (static head) - Cold
0.5 bar
Maximum CH system pressure (static head) - Hot
2.5 bar
Empty weight
45.5kg
Max lift weight
35kg
Total weight (full)
46.5kg
Electrical supply
230V - 50 Hz
Fuse at 3A
Internal fuses
F 4 amp ceramic
Maximum power consumption
160W
Max CH flow temperature
85°C
185°F
Integral expansion vessel capacity
8 ltr. capacity
Minimum clearances for installing and servicing the appliance refer to Fig. 1(b) below.
Gas 15mm
compression
Central heating flow
22mm compression
Central heating return
22mm compression
Domestic water inlet
15mm compression
Domestic water outlet
15mm compression
Pressure relief valve outlet
15mm tail
CONNECTION SIZES
2.4
GENERAL SPECIFICATIONS
1(b)
NOTE:
10mm for normal
operation 450mm for
installation and servicing
2.5
OVERALL DIMENTIONS AND MINIMUM CLEARANCES
The Seasonal Efficiency (SEDBUK) is 78.1 % and conforms with Band D. The efficiency value
is used in the UK Government Standard Assessment (SAP) for energy rating of dwellings.
Central Max 24
(82,000) 26.6
(90,900) 29.5
(100,890)
9.5
(3.8)
Heating Min. 11.6 (39,670) 13.5 (46,220) 15.0 (51,300)
2.5
(1.0)
DHW
Max 24 (82,000)
26.6 (90,900)
29.5 (100,890) 9.5 (3.8)
Min. 8.8 (30,000)
11.1 (36,360)
11.8 (40,350) 1.4 (0.5)
Factory
16.7 (57114) 18.6
(60000) 20.6
(70430)
6.0
(2.3)
set CH
MODE RATE OUTPUT
INPUT INPUT BURNER
Net
Gross
PRESSURE
kw (Btu/h) kw (Btu/h) kw (Btu/h) mbar (in.wg)
GENERAL
Central
Heating
DHW
Max gas rate (after 10 mins operation, i.e. hot)
3.6 m3/h
(128 ft3/h)
Factory set gas rate (after 10 min operation)
2.0 m3/h
(100 ft3/h)
Min. domestic hot water flow rate
2.8 l/min
(0.6 gpm)
Design domestic hot water performance
13.01 l/min (2.9 gpm) raised 35
∞
C
Max. domestic hot water temperature
73+/-2°C
Max. mains water inlet pressure
10 bar
(146 psi)
Min. mains water inlet pressure for operation
0.3 bar
(4.4 psi)
Min. mains water inlet pressure for max heat output
1.0 bar
(14.6 psi)
Max gas rate (after 10 mins operation, i.e. hot)
3.6 m3/h
(100 ft3/h)
The Seasonal Efficiency (SEDBUK) is 78.5 % and conforms with Band D. The efficiency value
is used in the UK Government Standard Assessment (SAP) for energy rating of dwellings.
Central Max 30
(102,400) 32.6
(111,547) 36.2
(123,800)
14.6
(5.8)
Heating Min. 11.0 (37,620) 13.5
(46,220) 14.2
(48,564)
2.4
(1.1)
DHW
Max 30
(102,400) 32.6
(111,547) 36.2
(123,800)
14.6
(5.8)
Min. 8.8
(30,000) 11.1
(36,360) 11.8
(40,350)
1.4
(0.5)
Factory
16.7 (57,114) 18.6
(60,000) 20.6
(70,430)
6.0
(2.3)
set CH
MODE RATE OUTPUT
INPUT INPUT BURNER
Net
Gross
PRESSURE
kw (Btu/h) kw (Btu/h) kw (Btu/h) mbar (in.wg)
GENERAL
Summary of Contents for Ace High
Page 8: ...8 EXPLODED DIAGRAM for key no references see spare parts catalogue Drawing amended 8 6 00 6 ...
Page 25: ...INTERNAL WIRING DIAGRAMS 7 7 1 FUNCTIONAL FLOW WIRING DIAGRAM 23 ...
Page 26: ...7 2 ILLUSTRATED WIRING DIAGRAM 24 ...
Page 40: ...Ace Ace High Wickes Combi 82 102 05 04 ACE ACE HIGH WICKES COMBI 82 102 ...