background image

Page 11

1000004727  (Rev. A - 09/18)

HAC-HB*1C     HAC-HB-NF-*1C

Fig. 8

Fig. 6

Fig. 7

BOTTLE FILLER INSTALLATION

WALL 

MOUNTING 

PLATE

BOTTLE FILLING 

UNIT

BOTTLE  FILLER  INSTALLATION

1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 6 - above). Remove top cover. Note do not discard mounting 

  screws, they will be needed to reinstall top cover. 

2) Remove wall mounting plate from Bottle Filler. Place wall plate against wall on top of basin. Center the wall plate side to side with the basin. Mark the 

  six (6) mounting holes with a pencil (See Fig. 7 - above). 

3) Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. 

4) Install wall mounting plate to wall using six (6) 7/16” obround mounting holes (mounting bolts not included) (See Fig. 7 - above). Use appropriate fasteners for your 

     wall type. 

5) Feed power cord & 3/8” water line through hole in tower/basin gasket (See Fig 9, Page 12).

6) Install gasket on bottom of bottle filler tower with gasket support bracket & (2) screws (See Fig 10, Page 12). 

7) Lay Bottle Filler on water cooler basin and cut insulation from tube even with bottom of gasket, remove this insulation from the 3/8” tube, but do not discard.  

  Feed the power cord and waterline through the hole on top of water cooler. NOTE: To prevent scratching the basin place a towel or soft cloth over the entire basin 

when working above it. 

8) With the power cord and waterline through hole on top of water cooler place Bottle Filler on the three (3) angled tabs protruding from the wall (See Fig. 8 - above)

  mounting plate, installed on wall. Make sure round boss in gasket fits in hole of basin. 

9) Once Bottle Filler is installed on wall plate tabs, water line, and power cord are installed properly, push top of Bottle Filler toward wall and line up top cover 

  two (2) holes. 

10) Reinstall Top Cover on Bottle Filler (See Fig. 6 -  above) with two mounting screws from step 1 above. Caution, do not over tighten screws. 

11) Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” water line to

       the tee. 

12) Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. 

      NOTE: If existing plumbing rough-in locations (Drain, Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet the filter can be

      installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler. 

13) Turn water supply on and inspect for leaks. Fix all leaks before continuing. 

14) Once unit has been inspected for leaks and any leaks found corrected, plug Bottle Filler and Cooler Unit into wall. Be sure to reinstall fuse to the circuit or switch   

      the circuit breaker back to the “ON” position. 

15) Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter. 

16) Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses might have 

      air in line which may cause a sputter. This will be eliminated once all air is purged from the line. 

17) Once unit tests out, install Lower Panel back on water cooler(s). Unit is now ready for use.

7/16” BOLT  HOLES FOR  

FASTENING UNIT TO WALL

UNIT CENTER LINE

TOP COVER

MOUNTING 

SCREWS

Summary of Contents for HydroBoost HTHB-HAC

Page 1: ...CTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEE...

Page 2: ...Before proceeding Disconnect electrical power supplying the water cooler Switch circuit breaker OFF or remove fuse Unplug water cooler power cord from electrical outlet Shut off water supply NOTE On T...

Page 3: ...emove the protective covering from the basin Reinstall the drain elbow drain plug and strainer plate on to the new basin Attach the new drain hardware onto the new basin Exchange Bubbler hardware WATE...

Page 4: ...ck the o rings Loosen the locknut and push tube end past both o rings to a positive stop in the filter head recess approx 1 Locknut may have to be backed out a little more Screw the locknut hand tight...

Page 5: ...filter and the water inlet using the supplied 3 8 x3 8 union connector Discard in line strainer Single Level Models Two Level Models HWF3000 WATERSENTRY PLUS FILTER INSTALLATION With Filter Fig 1 Sing...

Page 6: ...into insulation Insert 1 4 poly tube into the Regulator Outlet unmarked Opposite end of 1 4 poly tube will be inserted later into the Bubbler RE PLUMBING SINGLE STATION WATER CIRCUITS NON FILTER CAUTI...

Page 7: ...ut the Evaporator Outlet 1 4 poly tubing 6 from the Evaporator Outlet and insert the 1 4 Tee fitting between the two pieces Connect Bottle Filler supply line to Tee fitting Remove 1 4 poly tubing from...

Page 8: ...TOR L H DUMMY UNIT R H REFRIGERATED UNIT HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON RH SIDE SEE NOTE 2 1 Add water supply to Bottle Filler to be located on LH unit In the left hand unit cut th...

Page 9: ...D UNIT CAUTION This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly When disconnecting water lines use a container to catc...

Page 10: ...w Basin Assembly Reposition Basin Assembly Basin with Drain and Bubbler hardware back onto the cooler Reattach drain line to P trap and tighten 3 Fasten Basin Assembly in place Insert and retighten th...

Page 11: ...ound boss in gasket fits in hole of basin 9 Once Bottle Filler is installed on wall plate tabs water line and power cord are installed properly push top of Bottle Filler toward wall and line up top co...

Page 12: ...Page 12 1000004727 Rev A 09 18 HAC HB 1C HAC HB NF 1C BOTTLE FILLER GASKET Fig 9 Fig 10...

Page 13: ...ill scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button...

Page 14: ...Mtg Brkt John Guest Fittings Screws 1 2 3 55898C 98926C 0000000746 DESCRIPTION PART NO FILTER PARTS LIST See Fig 12 DESCRIPTION 98543C 98544C 1000004573 98546C 98547C 98549C 98668C 98669C 98670C 0000...