Page 7
1000004727 (Rev. A - 09/18)
HAC-HB*1C HAC-HB-NF-*1C
RE-PLUMBING SINGLE STATION WATER CIRCUITS (WITH FILTER)
CAUTION:
•
This procedure MUST be performed on ALL SINGLE HALSEY TAYLOR WATER COOLERS or the bottle
filling unit
WILL NOT perform properly!
•
When disconnecting water lines use a container to catch any water running out of the lines.
FILTER
HAC Hydroboost PLUMBING
1) Connect Water Supply From Filter to Evaporator:
•
Remove the in-line strainer outlet tube from
the Regulator Inlet.
• Remove the 1/4" copper tubing from the
regulator Outlet.
•
Connect the Filter outlet using 1/4” poly
tubing to the Evaporator 1/4” copper inlet
using the supplied 1/4” union.
2) Add water supply to Bottle Filler:
•
Cut the Evaporator Outlet 1/4” poly tubing
6” from the Evaporator Outlet and insert
the 1/4” Tee fitting between the two pieces.
• Connect Bottle Filler supply line to Tee fitting.
• Remove 1/4” poly tubing from Bubbler.
3) Re-route water supply to Regulator:
•
Insert end of 1/4” poly tubing from the Tee fitting
to the Regulator Inlet. which is marked with
the word “IN” on the Regulator.
4) Connect water supply from Regulator to Bubbler.
•
Cut a 12” piece of 1/4” poly tube along with
matching length of insulation.
•
Insert 1/4” poly tube into insulation.
•
Insert 1/4” poly tube into the Regulator Outlet
(unmarked).
•
Opposite end of 1/4” poly tube will be Inserted
later into the Bubbler.
Fig. 3
IN-LINE
STRAINER
STANDARD HAC PLUMBING
1/4”UNION
EVAPORATOR
INLET
EVAPORATOR
6” TUBING
TEE
EVAPORATOR
OUTLET
12” TUBING
REGULATOR
TO BOTTLE
FILLER
TO BUBBLER
EVAPORATOR
EVAPORATOR
INLET
REGULATOR
EVAPORATOR
OUTLET
TO BUBBLER