1) Connect Water Supply:

 • 

Remove the in-line strainer outlet tube from

    the Regulator Inlet.

 

• Remove the 1/4” copper tubing from the

      Regulator Outlet. 

 • 

Connect the in-line Strainer Outlet using 1/4”

    poly tubing to the Evaporator 1/4” copper

    inlet using the supplied 1/4” union.

2) Add water supply to Bottle Filler:

 • 

Cut the Evaporator outlet 1/4” poly tubing 

      6” from the Evaporator Outlet and insert    

    the 1/4” Tee fitting between the two pieces.

 

• Connect Bottle Filler supply line to tee fitting.

 

 

• Remove 1/4” poly tubing from Bubbler.

3) Re-route water supply to Regulator Inlet:

 • 

Insert end of 1/4” poly tubing from the 

    Tee fitting to the Regulator Inlet which is

    marked with the word “IN” on the regulator.

4) Connect water supply from Regulator to Bubbler:

 • 

Cut a 12” piece of 1/4” poly tube along with   

    matching length of insulation.

 • 

Insert 1/4” poly tube into insulation.

 

 Insert 1/4” poly tube into the Regulator

      Outlet (unmarked).

 

• 

Opposite end of 1/4” poly tube will be

    inserted later into the Bubbler.

RE-PLUMBING SINGLE STATION WATER CIRCUITS (NON-FILTER)

CAUTION:

 • 

This procedure MUST be performed on ALL SINGLE HALSEY TAYLOR WATER COOLERS or the bottle  

 

   filling unit 

WILL NOT perform properly!

 • 

When disconnecting water lines use a container to catch any water running out of the lines.

IN-LINE

STRAINER

REGULATOR

1/4”UNION

REGULATOR

TEE

TO BOTTLE 

FILLER

6” TUBING

EVAPORATOR 

INLET

EVAPORATOR 

OUTLET

EVAPORATOR 

OUTLET

EVAPORATOR

 

STANDARD HAC PLUMBING

 HAC Hydroboost PLUMBING

Fig. 2

IN-LINE

STRAINER

12” TUBING

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

TO BUBBLER

TO BUBBLER

EVAPORATOR

 

EVAPORATOR 

INLET

Summary of Contents for HydroBoost HTHB-HAC

Page 1: ...CTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEE...

Page 2: ...Before proceeding Disconnect electrical power supplying the water cooler Switch circuit breaker OFF or remove fuse Unplug water cooler power cord from electrical outlet Shut off water supply NOTE On T...

Page 3: ...emove the protective covering from the basin Reinstall the drain elbow drain plug and strainer plate on to the new basin Attach the new drain hardware onto the new basin Exchange Bubbler hardware WATE...

Page 4: ...ck the o rings Loosen the locknut and push tube end past both o rings to a positive stop in the filter head recess approx 1 Locknut may have to be backed out a little more Screw the locknut hand tight...

Page 5: ...filter and the water inlet using the supplied 3 8 x3 8 union connector Discard in line strainer Single Level Models Two Level Models HWF3000 WATERSENTRY PLUS FILTER INSTALLATION With Filter Fig 1 Sing...

Page 6: ...into insulation Insert 1 4 poly tube into the Regulator Outlet unmarked Opposite end of 1 4 poly tube will be inserted later into the Bubbler RE PLUMBING SINGLE STATION WATER CIRCUITS NON FILTER CAUTI...

Page 7: ...ut the Evaporator Outlet 1 4 poly tubing 6 from the Evaporator Outlet and insert the 1 4 Tee fitting between the two pieces Connect Bottle Filler supply line to Tee fitting Remove 1 4 poly tubing from...

Page 8: ...TOR L H DUMMY UNIT R H REFRIGERATED UNIT HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON RH SIDE SEE NOTE 2 1 Add water supply to Bottle Filler to be located on LH unit In the left hand unit cut th...

Page 9: ...D UNIT CAUTION This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS or the bottle filling unit WILL NOT perform properly When disconnecting water lines use a container to catc...

Page 10: ...w Basin Assembly Reposition Basin Assembly Basin with Drain and Bubbler hardware back onto the cooler Reattach drain line to P trap and tighten 3 Fasten Basin Assembly in place Insert and retighten th...

Page 11: ...ound boss in gasket fits in hole of basin 9 Once Bottle Filler is installed on wall plate tabs water line and power cord are installed properly push top of Bottle Filler toward wall and line up top co...

Page 12: ...Page 12 1000004727 Rev A 09 18 HAC HB 1C HAC HB NF 1C BOTTLE FILLER GASKET Fig 9 Fig 10...

Page 13: ...ill scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button...

Page 14: ...Mtg Brkt John Guest Fittings Screws 1 2 3 55898C 98926C 0000000746 DESCRIPTION PART NO FILTER PARTS LIST See Fig 12 DESCRIPTION 98543C 98544C 1000004573 98546C 98547C 98549C 98668C 98669C 98670C 0000...