Page 8
1000004727 (Rev. A - 09/18)
HAC-HB*1C HAC-HB-NF-*1C
Fig. 4
RE-PLUMBING TWO LEVEL STATION WATER CIRCUITS (NON-FILTER)
HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON LH SIDE (SEE NOTE 1)
STANDARD HAC TWO LEVEL PLUMBING WITHOUT BOTTLE FILLER
TO BUBBLER
REGULATOR
EVAPORATOR
INLET
EVAPORATOR
TO BUBBLER
EVAPORATOR
OUTLET
TEE
TO BOTTLE
FILLER
IN-LINE STRAINER
L.H. DUMMY UNIT
L.H. DUMMY UNIT
R.H. REFRIGERATED UNIT
R.H. REFRIGERATED UNIT
TO BUBBLER
REGULATOR
IN-LINE STRAINER
EVAPORATOR
INLET
TO BUBBLER
REGULATOR
EVAPORATOR
OUTLET
EVAPORATOR
REGULATOR
IN-LINE STRAINER
TO BUBBLER
REGULATOR
TO BOTTLE
FILLER
EVAPORATOR
INLET
EVAPORATOR
OUTLET
EVAPORATOR
TO BUBBLER
REGULATOR
L.H. DUMMY UNIT
R.H. REFRIGERATED UNIT
HAC TWO LEVEL Hydroboost PLUMBING BOTTLE FILLER ON RH SIDE (SEE NOTE 2)
1) Add water supply to Bottle Filler to be located on LH unit:
•
In the left hand unit, cut the Evaporator outlet 1/4” poly tubing approx. 5” from the access opening between the units,
insert the 1/4” Tee fitting between the two pieces and connect 3/8” water line to tee.
2) Add water supply to Bottle Filler to be located on RH unit:
•
In the right hand unit, cut the Evaporator outlet 1/4” poly tubing approx. 2” from the access opening between the units,
insert the 1/4” Tee fitting between the two pieces and connect 3/8” water line to tee.
CAUTION:
• This procedure MUST be performed on ALL TWO LEVEL HALSEY TAYLOR WATER COOLERS
or the bottle filling unit
WILL NOT perform properly!
• When disconnecting water lines use a container to catch any water running out of the lines.