4: Operating the JAZ-PX Module
28
013-RD000-000-02-201510
Menu Item
Description
Intensity
Controls the discharge voltage (and thus the flash intensity) of the lamp. Select
400-600V. On battery power, the intensity is restricted to 400V.
Number of Flashes Sets the number of times that the lamp should flash after detecting a trigger event.
Holdoff Time
Specifies how long the timing generator should wait after detecting a trigger event
before beginning to flash at the rate specified by the Flash Rate parameter.
Timing Controls
Controls used to set the timing behavior of the JAZ-PX module.
Force Trigger
An emulated trigger signal that can be used to force trigger events on the JAZ-PX
module at any time. Forcing a trigger causes a trigger event with the same
behavior as if the device detected a stack trigger. Force Trigger will not have any
effect when the device is in Free Running mode, but it is not masked by turning
Trigger Enable off.
Timing Reset
Does not reset the timing parameters themselves. Instead, it resets the state of the
counters keeping track of timing in the hardware. This can be useful
to “escape”
from long flash periods or large values set in the Number of Flashes parameter.
Free Running
Puts the device into Free Running mode. In this mode, the timing generator simply
flashes the lamp at the rate that is specified by the Flash Rate parameter and
ignores trigger events.
Run Forever
When enabled, the timing generator will enter Run Forever mode. In this mode, it
will ignore the Number of Flashes parameter setting and continue flashing forever
once it has received a trigger event. It will re-sync to any trigger events that are
detected during that time.
Output Enable
When disabled, the lamp will not flash. When set to 1, the lamp will flash as
normal.
Trigger Enable
When enabled, the timing generator will not detect trigger events that are
generated by the stack trigger. It
will
still detect timing events that are generated by
the forced trigger.
Advanced Settings
Provides the advanced capability to set parameters and controls directly on the
device, bypassing the Jaz menus. It also contains the power management menu.
Write Register
Allows you to write values directly to the control registers of the JAZ-PX module.
Read Register
Allows you to write values directly to the control registers of the JAZ-PX module.
Power Mode
Sets the power mode of the JAZ-PX module to either battery power or external
power. You must manually set the power mode to external power to access
intensities greater than 0 (400V) and flash rates higher than 200 Hz (5 msec).
Using the JAZ-PX module on Jaz battery power at flash rates greater than 200 Hz
can result in unexpected behavior.
Summary of Contents for Ocean Optics JAZ
Page 6: ...Table of Contents iv 013 RD000 000 02 201510 ...
Page 10: ...About This Manual viii 013 RD000 000 02 201510 ...
Page 18: ...1 Introduction 8 013 RD000 000 02 201510 ...
Page 26: ...3 Operating Jaz 16 013 RD000 000 02 201510 Jaz Main Menu for DPUs dated January 1 2008 ...
Page 28: ...3 Operating Jaz 18 013 RD000 000 02 201510 Jaz Main Menu for DPUs dated after January 1 2008 ...
Page 31: ...4 Operating Jaz 013 RD000 000 02 201510 21 for DPUs after January 1 2008 ...
Page 35: ...4 Operating the JAZ PX Module 013 RD000 000 02 201510 25 JAZ PX Menu JAZ PX Menu Tree ...
Page 36: ...4 Operating the JAZ PX Module 26 013 RD000 000 02 201510 ...
Page 44: ...4 Operating the JAZ PX Module 34 013 RD000 000 02 201510 ...
Page 46: ...5 Operating the JAZ INDY Module 36 013 RD000 000 02 201510 JAZ INDY Menu ...
Page 47: ...5 Operating the JAZ INDY Module 013 RD000 000 02 201510 37 ...
Page 48: ...5 Operating the JAZ INDY Module 38 013 RD000 000 02 201510 ...
Page 49: ...5 Operating the JAZ INDY Module 013 RD000 000 02 201510 39 ...
Page 54: ...5 Operating the JAZ INDY Module 44 013 RD000 000 02 201510 ...
Page 60: ...6 Maintenance 50 013 RD000 000 02 201510 ...