HSM-44-BX
8
© Copyright 2018 Hall Research, Inc.
1.
To blank an output, hold the Output button for 3 seconds or until its led
starts blinking.
2.
Press SET to apply the change. The blanked Output will be crossed on the
front panel LCD with an “X”, indicating that it is blanked.
Example:
Blanking output 1
You can also blank all the outputs that are connected to a particular input.
1.
Hold the input for 3 seconds.
2.
Press SET to apply the change. All the affected output ports and blanked
3.3 Presets (Memorized Routing Patterns)
The number of presets accessible from the front panel is the same as the total #
of input buttons. Each front panel input button can memorize a pattern.
Therefore, you can recall 4 presets.
3.3.1 Saving ongoing configuration as a Preset
1.
To save ongoing configuration as a preset, hold PRE button for 3 seconds
until it blinks.
2.
Select preset position by pressing an input button
3.
Press SET to save the pattern as a Preset in that key position.
Example:
Saving ongoing configuration as Preset #1
3.3.2 Recalling Presets
1.
To recall a saved preset, press the PRE button.
2.
Select the desired Preset # by pressing an input button.