background image

 

 

 

 

 

 

 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

© Copyright 2018. Hall Research, Inc. 

All rights reserved. 

 
 
 

1163 Warner Ave., Tustin, CA 92780 

Ph:  (714)641-6607 

 

Summary of Contents for HSM-44-BX

Page 1: ...IR RS 232 IP and Power over HDBaseT to 100meters RS 232 IP IR and Front panel Control with Status LCD Display Analog and Digital Extracted Audio Outputs UMA1251 Rev A Order toll free in the U S 800 9...

Page 2: ......

Page 3: ...nection Diagram 4 3 2 General Operation 5 3 3 Presets Memorized Routing Patterns 8 3 4 Using the IR Remote to route video 9 3 5 Rear Panel 10 3 6 IR Detector and Emitter Cables 11 4 0 Recommended HDBa...

Page 4: ...ce to radio communication It has been designed to comply with the limits for a Class B computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are intended to...

Page 5: ...0 It also supports HDCP 2 2 and 1 4 3D deep color PCM Dolby DTS and HD audio standards The matrix intelligently calculates EDID for each input based on the EDID of the connected sinks Users are able...

Page 6: ...must provide their own cord 1 IR Remote 1 Rack mounting brackets 2 pcs 1 RS 232 Cable 6 IR Detectors for use on IR Input and IR EXT ports 5 IR Emitters for use on IR Output ports 8 3 Pin screw termina...

Page 7: ...the front panel buttons have built in LEDs to help with their operation Front panel functions are designed for maximum intuitiveness With just a little practice one can easily learn to monitor and con...

Page 8: ...ss the power button any time to turn ON the matrix For safe operation to turn the unit OFF you must hold the power button for 3 seconds 3 2 5 Making AV Routing or Ties from the Front Panel Hall Resear...

Page 9: ...similar to the above but an input can be routed to multiple outputs 1 Press one of the input buttons That button will light up in solid along with ALL the outputs currently routed from that input Note...

Page 10: ...blanked 3 3 Presets Memorized Routing Patterns The number of presets accessible from the front panel is the same as the total of input buttons Each front panel input button can memorize a pattern The...

Page 11: ...end just like making ties from the output end Holding an entry will clear the output Unassigned outputs will be blanked by default 4 Press SET and select the preset number you want to copy Note that...

Page 12: ...onnector Note that the IR signals that are being extended via HDBaseT are located in their own grouping as shown in the Rear panel image above The Ethernet that extends via HDBaseT is also its own con...

Page 13: ...x and can be used to send or receive IR signals to compatible HDBaseT Receivers such as the HBX R IR input group has individual inputs 1 4 and one input labeled ALL If you plug an IR detector cable to...

Page 14: ...and Ethernet ports A main advantage of using the HBX R is that even though they are shipped with a 5v power supply when connected to the HSM 44 BX they get power via the HDBaseT Cat6 from the matrix a...

Page 15: ...ption allows the user to choose a specific EDID table and load it into any selected input port on the matrix HSM 44 BX comes with 15 common EDIDs saved in its internal memory or you can copy the EDID...

Page 16: ...new EDID for that input based on the TV with minimum resolution capability Therefore in this mode if the EDID changes a short interruption may result in the video signal from the source as it changes...

Page 17: ...ne Stop 1 bit Commands are in ASCII format Commands are case sensitive Use a single CR character to terminate each command Responses from the Matrix are terminated with CR LF Other than Power command...

Page 18: ...1 4 m Input 1 4 CV Query all the outputs CV1 CV4 PSx x Preset number 1 to 4 Preset Save Saves the current configuration as a preset PSx PSx 1 m 2 m 3 m 4 m m Input 1 4 m x to blank the output Define a...

Page 19: ...IGH Source Active HDn n Input 1 4 HDCP Query ON OFF ESi m m Input 1 4 i EDID Index 1 15 from table in section 5 1 Set EDID for a particular input m ESi m ESi i EDID Index 1 15 from table in section 5...

Page 20: ...he device is malfunctioning or you have no connectivity please try to use the following methods for troubleshooting Try Rebooting the device by removing and applying power Restore factory defaults FD...

Page 21: ...channel formats PCM2 PCM5 1 PCM7 1 Dolby5 1 DTS5 1 DD D TrueHD DTS HD 16 20 24 bits per sample and up to 96 KHz Sampling Rate Control Front Panel Telnet RS 232 IR Baud Rate 115200 bps Power Supply 110...

Page 22: ...HSM 44 BX 20 Copyright 2018 Hall Research Inc...

Page 23: ......

Page 24: ...Copyright 2018 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Ph 714 641 6607...

Reviews: