![background image](http://html1.mh-extra.com/html/hakko-electronics/monitouch-v7/monitouch-v7_user-manual_3318358244.webp)
5
4. HITACHI PLC
5-37
Co
nne
HIDIC-H: Switch Setting
Baud rate:
19200 bps
MODE switch:
To connect to both RS-232C and RS-422, set MODE switch to 9.
RS-232C (protocol 2 without port) RS-422 (protocol 2 with port)
ST No switch:
“0” for both
×
10,
×
1
DIP switch
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
HIDIC-H
Switch
Setting
Contents
1
OFF
Bit length
2
OFF
Same as that set on V7 (normally 19200 bps)
3
ON
4
ON
5
ON
With parity
6
ON
Even
7
OFF
Stop bit 1
8
ON
With sumcheck
Memory
TYPE
Remarks
WR
(internal word output)
0
X
(external bit input)
1
WX as word device
Y
(external bit output)
2
WY as word device
L
(bit CPU link area)
3
WL as word device
M
(bit data area)
4
WM as word device
TC
(timer counter/elapsed time)
5
R
(relay)
6
TD
(timer counter/contact)
7
WN
(network input/output)