![background image](http://html1.mh-extra.com/html/hakko-electronics/470b/470b_instruction-manual_3301766007.webp)
CAUTION
Be sure to turn the power switch off
before connecting or disconnecting
the cord assembly and the power
plug. Failure to do so may damage
the P.W.B.
CAUTION
The entire unit is constructed of
conductive materials. Always ground
the unit.
CAUTION : The desoldering gun must be placed in the iron
holder when not in use.
The power lamp doesn’t
light up.
1. Is the power cord properly
connected?
2. Is the fuse blown?
The nozzle doesn’t heat up.
1. Is the cord assembly
properly connected?
2. Is the heating element
broken?
Secure the plug by
turning it clockwise.
Fully insert the hose
into the vacuum
outlet cap.
Insert the cord
assembly by keying
the plug to the key
on the receptacle.
The power lamp
lights up.
The nozzle heats up.
Connections
·Connect the cord assembly to
the receptacle (marked "IRON").
·Connect the hose to the
vacuum outlet cap (marked
"VACUUM").
Power switch
·Confirm that the power switch
is set in the OFF position, then
connect the power plug to the
power source.
·Turn the power switch to ON.
The power lamp should light
up.
·The nozzle begins to heat up
as soon as the power switch
is turned to ON.
After turning the power
switch to ON, wait three (3)
minutes before beginning
desoldering operations.
6