Specifications
Wiring
22
H2
TRANS
TRANS
H1
M1
TR
M2
Receptacle
P.W.B.
Fuse Holder
4
2
3
1
2
1
2
1
4
4
1
1
Power Consumption
Name
HAKKO 470B
110W
Part Name
Output Voltage
24V
~
Vacuum Generator
Vacuum pump, double cylinder type
Vacuum Pressure (Max)
600 mm Hg (24 in Hg)
Suction Flow
15 / min.
Voltage Leakage
Under 2 mV (TYP. 1.2 mV)
Ground Resistance
Under 2
Outer Dimensions
(l x w x h)
260 x 165 x 135 mm
(10.24 x 6.50 x 10.24 in.)
Weight
Approx. 3.8 kg (8.4 lbs.)
Station
• Station
• Replacement Parts
Part Name
Part No.
C1054
Power Consumption
24V AC, 50W
Temperature
380˚C ~ 480˚C (716˚F ~ 896˚F)
Insulation Resistance
Over 300 M at 420˚C (790˚F)
Nozzle Inside Diameter
Ø1.0 (0.04 in) (Nozzle S, Standard)
Outer Dimensions
(w x h)
135 x 174 mm
(5.31 x 6.85 in.)
Weight
Approx. 200g (0.44 lbs.)
HAKKO 802
• Desoldering Gun
Part No.
A1002
Part. Name / Specification
Nozzle S Ø0.8 mm (0.03 in.)
A1003
Nozzle S Ø1.0 mm (0.04 in.)
A1004
Nozzle Ø0.8 mm (0.03 in.)
A1005
Nozzle Ø1.0 mm (0.04 in.)
A1006
Nozzle Ø1.3 mm (0.05 in.)
A1007
Nozzle Ø1.6 mm (0.06 in.)
Part No.
B1215
Part. Name / Specification
Cleaning Pin for Heating Element
B1086
Cleaning Pin for Ø0.8 mm (0.03 in.) Nozzle
Cleaning Pin for Ø1.0 mm (0.04 in.) Nozzle
Cleaning Pin for Ø1.3 mm (0.05 in.) Nozzle
Cleaning Pin for Ø1.6 mm (0.06 in.) Nozzle
Cleaning Drill for Ø0.8 mm (0.03 in.) Nozzle
Cleaning Drill for Ø1.0 mm (0.04 in.) Nozzle
Cleaning Drill for Ø1.3 mm (0.05 in.) Nozzle
Cleaning Drill for Ø1.6 mm (0.06 in.) Nozzle
B1087
B1088
B1089
B1302
B1303
B1304
B1305
Part No.
B1128
Part. Name / Specification
Filter Pipe w/ Front Holder & Filters
A1009
Ceramic Paper Filter (S) for Filter Case 10 pcs.
Ceramic Paper Filter (L) for Filter Pipe 10 pcs.
Spring Filter 10 pcs.
Heating Element 24V, 50W
Silicone Grease
Cleaning Sponge
A1033
A1030
A1029
A1028
A1042
¿A
¿B
¿A
¿B
ØA
ØB
A1002
0.8 (0.03 in.)
1.0 (0.04 in.)
1.8 (0.07 in.)
2.0 (0.08 in.)
A1003
Part No.
ØA
ØB
A1004
0.8 (0.03 in.)
1.0 (0.04 in.)
2.3 (0.09 in.)
2.5 (0.1 in.)
A1005
1.3 (0.05 in.)
3.0 (0.12 in.)
A1006
1.6 (0.06 in.)
3.0 (0.12 in.)
A1007
Part No.
Condition of Measurement
·Insulation Resistance
The insulation resistance was measured between the nozzle and the lead of the heating element using a 500 V DC insulation resistance meter.
Caution: The insulation resistance cannot be measured between the nozzle and the power plug as the transformer between the secondary part (heating element) and the primary part acts as an insulator.
·Voltage Leakage
The voltage leakage was measured between the nozzle and the grounding plug at a temperature of 480ûC (896ûF) using an AC mV meter.
Caution: Be sure to ground the unit before measuring the the voltage leakage.
·Specifications are subject to change without notice.
24V
Transformer
White
Black
Power Switch
Power Cord
Motor
(w/o cord, hose)