13.2 Fault table
Fault
Possible cause
Remedial action
Remedied by
Defective axial
strokes in the ad-
aptation clamping
device
Dirt in the parts in
the power flow
Remove and clean the clamping
element and, if necessary, re-
move, dismantle and clean the ad-
aptation clamping device
Skilled special-
ist
Incorrect coupling
position
Check the coupling position and
align with the adaptation clamping
device
Clamping element
cannot be
swapped in or out
Defective axial
strokes in the ad-
aptation clamping
device
See fault »Defective axial strokes
in the adaptation clamping de-
vice«
Adaptation clamp-
ing element cannot
be swapped in or
out
Defective axial
strokes in the basic
clamping device
See operating instructions for the
basic clamping device
Adaptation clamp-
ing device not un-
locked
Unlock the adaptation clamping
device manually [see »Unlocking
the adaptation clamping device
manually« chapter]
Skilled special-
ist
The coupling slid-
ers do not move
automatically
Clean the adaptation clamping de-
vice
Skilled special-
ist
Clamping force is
too weak
Workpiece outside
the clamping width
diameter
Use a suitable clamping element
Skilled special-
ist
Axial actuation
force is too weak
Check machine setting and cor-
rect if necessary
Stroke limitation by
the workpiece end-
stop
Use an appropriate workpiece
end-stop
Clamping force is
too high
Axial actuating
force is too high
Check machine setting and cor-
rect if necessary
Skilled special-
ist
Geometry devia-
tion on the work-
piece
Axial run-out error
on the adaptation
clamping device
Check axial run-out of the adapta-
tion clamping device and clean the
mating surfaces and locating taper
if necessary
Skilled special-
ist
Face run-out error
on the adaptation
clamping device
Check face run-out of the adapta-
tion clamping device and clean the
mating surfaces and locating taper
if necessary
Dirty end-stop area
Remove the workpiece end-stop
and clean the mating surfaces