MANDO Adapt T211
Commissioning
56
Order h49 7144.907-333
Pay attention to the level of actuating force established
to enable the workpiece to be clamped with sufficient
clamping force.
Do not exceed the maximum actuating force indicated
on
the
product.
Always take the lowest value of all actuating forces indi-
cated for combined products.
All installation tools are removed from the machining
area.
Clamping device and workpiece are compatible - check
clamping diameter on a regular basis.
Conduct a clamping force measurement.
8.4 Workpiece
DANGER
Serious injuries caused by parts being ejected
centrifugally if level of workpiece clamping is in-
sufficient!
Never utilize the full clamping reserve.
Do not exceed the permitted maximum clamping
reserve stroke.
The remaining clamping reserve must always be
adapted to suit the workpiece material provided
and its possible distortions.
WARNING
Crushing injuries to hands / fingers is workpiece
is installed incorrectly!
Do not place hands / fingers between workpiece
and clamping device.
Never reach into the clamping area.
CAUTION
Burns caused by high workpiece temperature!
Give preference to automatic loading.
Also wear the following items of personal protec-
tive equipment, in addition to the basic equip-
ment: