![Haier GE GFD14ESSNWW Technical Service Manual Download Page 33](http://html1.mh-extra.com/html/haier/ge-gfd14essnww/ge-gfd14essnww_technical-service-manual_3322820033.webp)
– 33 –
3. Press the tabs on the sides of LED light to
remove it from the drum light cover to replace
the LED.
4. Pull the lite assembly into the drum to remove.
Press
Press
Outlet Thermistor (NTC1)
The outlet thermistor is located on the back of the
blower housing.
The thermistor measures drum outgoing air
temperature and responds to temperature
changes.
The control board makes heating decisions based
on this information.
Outlet Thermistor Removal
1. Remove the front panel (see
Front Panel
in the
Dryer Components
section of this
service guide). Disconnect the wire harness
connector.
2. Remove the two Phillips-head screws
securing the thermistor to the blower housing.
The thermistor has a negative temperature
coefficient (as temperature increases, resistance
decreases).
Resistance can be measured at the thermistor
wire harness. Make sure to disconnect the wire
harness to isolate the thermistor before taking
readings.
Operation of the thermistor can be checked by
using the service mode test t07 (see
Service
Mode Test
in the
Diagnostics
section of this
service guide).
Specific faults associated with the outlet
thermistor can initiate Fault Code E4 (see
Fault Codes
in the
Diagnostics and Service
Information
section of this service guide).
Temperature °F
Approx. Ω (Ohms)
68°F
12.32 - 12.66kΩ
104°F
5.22 - 5.43kΩ
140°F
2.41 - 2.57kΩ