Functions and control
20 Domestic air conditioner
During the starting process of the compressor, if the AC current is greater than 13.5/14A(18K/24K),
the frequency of the compressor decreases at the speed of 0.1HZ/second.
During the starting process of the compressor, if the AC current is greater than 13A/13A(18K/24K),
the frequency of the compressor increases at the prohibited speed.
During the starting process of the compressor, if the AC current is greater than 11.5A/12A(18K/24K),
the frequency of the compressor increases at the speed of no faster than 0.1HZ/second.
Remarks: when the outdoor temperature is high, there’s compensation for AC current protection.
(1) When the outdoor environment temperature is higher than 40
ć
, AC current protection value
decreases by 2.5A/1A(18K/24K).
(2) When the outdoor environment temperature is higher than 50
ć
, AC current protection value
decreases by 3.5A/2A(18K/24K).
7.1.5.5 Anti-freezing protection of the indoor heat exchanger
When refrigerating/heating, prevent freezing.
Tpg_indoor is the minimum value of the effective indoor unit (start it and it is in accord with the running
state).
11
ć
//ice5
ice3 9
ć
Increasing slowly
8
ć
//ice2
Keeping the frequency
ice_temp_3 7
ć
7
ć
ice_temp_2 5
ć
Decreasing slowly
ice_temp_1 3
ć
Decreasing rapidly ice_temp_1
1
ć
Stop
When Tpg_indoor
LJ
ice_temp_1, the frequency of the compressor decreases at the speed of
1HZ/1second.
When Tpg_indoor
LJ
ice_temp_2, the frequency of the compressor decreases at the speed of
1HZ/10seconds.
When Tpg_indoor begins to rise again, and ice_temp_2
İ
Tpg_indoor
İ
ice_temp_3, the frequency
of the compressor doesn’t change.
When ice_temp_3
LJ
Tpg_indoor
LJ
ice3
ć
, the frequency of the compressor increases at the
speed of 1HZ/10seconds.
For example, Tpg_indoor
İ
0
ćˈ
last for 2 minutes, and then the outdoor unit will stop, and report
underload malfunction, but don’t send malfunction report to the indoor.
The compressor stops for more than 3 minutes, Tpg_indoor> ice2
ć
, the compressor
recovers.
7.1.5.6 The frequency limitation of modification rate
In the field which is controlled by high frequency, if the modification rate is not high enough, the
Summary of Contents for 1U68REMFRA
Page 11: ...Pinping diagrams Domestic air conditioner 4ˊPiping diagrams 9 EEV EEV ...
Page 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40 ...
Page 39: ...Service diagnosis 37 Domestic air conditioner ...
Page 46: ...Service diagnosis 44 Domestic air conditioner ...
Page 58: ...58 Do C omestic air ircuit Diagra conditioner ams r 12 2 Module board circuit diagram ...
Page 59: ...57 Do C omestic air ircuit Diagra conditioner ams r ...