Service diagnosis
Domestic air conditioner
10 Service Diagnosis
10.1 Caution for Diagnosis
The operation lamp flashes when any of the following errors is detected.
1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions,
disabling equipment operation.
2. When a signal transmission error occurs between the indoor and outdoor units. In either case, conduct the
diagnostic procedure described in the following pages.
Parameter of primary electronic appliance
e
r
u
t
c
i
p
r
e
t
e
m
a
r
a
p
e
m
a
n
Compressor
Rated voltage:220-230V
Rated current:4.8A
Rated frequency: 50/60HZ
Fan motor
Rated voltage:220-230V
Rated current:0.2A
Rated frequency: 50/60HZ
Reactor
Rated voltage:220-230V
Rated current:10.5A
Rated frequency: 50/60HZ
4-way valve
Rated voltage:220-230V
Rated current:0.1A
Rated frequency: 50/60HZ