Service diagnosis
32 Domestic air conditioner
10.3 Error Codes and Description indoor display
Code indication
fault description
Reference
Page
Indoor displaying panel code
indication
Outdoor
(LED1
flash
times)
Other
display
Only For 498 and
498A display
(Red/Green Time Run
ƶ2Qƾ)ODVKƵ2II
,)
Indoor and
Outdoor
E7
ƵƵƾ
15
Communication fault
between indoor and
outdoor units
Page .43
Indoor
Malfunction
E1
ƾƵƵ
--
Room temperature sensor
failure
Page 33
E2
ƾƶƶ
--
Heat-exchange sensor
failure
Page 33
E4
ƾƶƾ
--
Indoor EEPROM error
Page 34.
E9
ƾƾƾ
21
High-work intense
protection
Page 46
E14
Ƶƶƾ
--
Indoor fan motor
malfunction
Page 35
Outdoor
Malfunction
F12
ƵƾƵ
1
Outdoor EEPROM error
Page .34
F1
ƶƾƾ
2
The protection of IPM
Page .38
F22
ƾƾƵ
3
Overcurrent protection
of AC electricity for
the outdoor model
Page .39
F3
ƵƾƵ
4
Communication fault
between the IPM and
outdoor PCB
Page.40
F19
Ƶƾƶ
6
Power voltage is too high
or low
Page .41
F4
ƵƾƵ
8
Overheat protection for
Discharge temperature
Page .42
F21
ƶƶƾ
10
Defrost temperature
sensor failure
Page 33
F7
ƵƾƵ
11
Suction temperature
sensor failure
Page.33
F6
ƶƾƵ
12
Ambient temperature
sensor failure
Page 33
F25
ƾƶƵ
13
Discharge temperature
sensor failure
Page 33
F11
ƵƾƵ
18
deviate from the normal
for the compressor
Page .45
F28
ƵƾƵ
19
Loop of the station
detect error
Page .45
F2
Ƶƾƶ
24
Overcurrent of the
compressor
Page .39
F8
Ƶƾƶ
9
Outdoor DC fan motor
fault
Page 36
F23
Ƶƾƶ
25
Overcurrent protection for
single-phase of the
compressor
Page .39
Summary of Contents for 1U68REMFRA
Page 11: ...Pinping diagrams Domestic air conditioner 4ˊPiping diagrams 9 EEV EEV ...
Page 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40 ...
Page 39: ...Service diagnosis 37 Domestic air conditioner ...
Page 46: ...Service diagnosis 44 Domestic air conditioner ...
Page 58: ...58 Do C omestic air ircuit Diagra conditioner ams r 12 2 Module board circuit diagram ...
Page 59: ...57 Do C omestic air ircuit Diagra conditioner ams r ...