TO RINSE SOLUTION TANK:
1. Solution pump switch should be in the “ON” position
(fig. 4.55).
2. Turn on spray system monitor. Turn the rate switch to
the “MANUAL” position. Using the flow increase/
decrease lever, increase solution pressure to maximum
PSI.
3. Close the solution tank valve (fig. 4.56, item 2).
4. Depress the “SOLU TANK” rinse switch (fig. 4.56, item
3).
5. Momentarily activate and then deactivate agitation (fig.
4.56, item 1).
6. When finished rinsing the solution tank return the rinse
switch back to the “OFF“ position and turn the spraying
system off (including solution pump switch, and
monitor).
Rinse System Operation
NOTE:
Select a safe area to rinse spray system
and clean sprayer where the chemicals
will not drift off to contaminate people,
animals, vegetation, or water supply.
44
NOTE:
Refer to chemical manufacturer’s guide
for
types
of
cleaning
solution
combinations (plain water, cleaning
agents, etc.).
IV.
OPERATING INFORMATION
FIG 4.55
NOTE:
Activate the rinse system only after
solution tank is empty.
TO RINSE BOOM SUPPLY AND NOZZLES:
1. Follow steps 1 and 2 from above.
2. Turn agitation off (fig. 4.56, item 1).
3. Close solution tank valve (fig. 4.56, item 2) and open
boom supply valves (fig. 4.56).
4. Depress the “BOOM” rinse switch (fig. 4.56, item 3).
5. When finished rinsing the boom return rinse switch back
to the “OFF” position and turn the spraying system off
(including solution pump switch, monitor, boom solution
valves and main spray power switch).
FIG 4.56
1
3
2
Summary of Contents for STS12