7-45
SECTION 7 –
SPRAY SYSTEMS
7. Press and hold the Pump Speed Switch
in the DOWN (Off) position when filling is
complete.
8. Push the Pump Activation Lever DOWN.
NOTE: The following procedures are the
same for either a sprayer-mounted
transfer pump or a nurse tank pump.
Fill Water Only
• Fill Port (G) -
CONNECTED
• Fill Valve (H) -
OPEN
• Chemical Inductor Valve (C) -
CLOSED
• Side Fill Valve (A) -
OPEN
• Swirl Valve (E)
-
CLOSED
Fill Water/Induct Chemical
• Fill Port (G) -
CONNECTED
• Fill Valve (H) -
OPEN
• Side Fill Valve (A)
-
CLOSED
• Chemical Inductor Valve (C)
-
OPEN
(after flow
is established)
Fill Water/Induct Dry Chemical
• Fill Port (G) -
CONNECTED
• Fill Valve (H) -
OPEN
• Side Fill Valve (A) -
CLOSED
• Swirl Valve (E)
-
OPEN
NOTE: Allow water to fill chemical tank
approximately 3 inches (7.6 cm)
before adding dry chemical. Add dry
chemical with the Swirl Valve (E)
OPEN. Open the Chemical Inductor
(E) after dry chemical has been
added.
Fill Rinse Tank
• Rinse Supply Valve (B) -
OPEN
Rinse Inductor Tank
• Swirl Valve (E) -
OPEN
NOTE: Before raising the Inductor
Assembly, the Chemical Inductor
Tank must be in the LOCKED
position.
Rinsing the Side Fill
1. Remove Fill Port cap.
2. Attach fresh water supply connection to
Fill Port.
3. Turn fresh water supply ON.
4. Rotate the Fill Valve (H) in the OPEN
position.
5. Rotate the Side Fill Valve (A) in the
OPEN position.
6.
When rinsing is complete
, turn fresh
water supply OFF.
7. Close the Fill Valve and Side Fill Valve.
8. Remove fresh water supply connection
from Fill Port and reinstall cap.
Rear Fill
-If Equipped
Filling the Solution Tank
1. Remove fill port cap and connect solu-
tion supply to the Solution Tank Fill Port
(located behind rear left-hand wheel).
2. Rotate Solution Tank Fill Valve to the
OPEN position and fill tank to desired
level.
3.
When finished filling the tank,
close
the Solution Tank Fill Valve.
4. Remove solution supply from the Solu-
tion Tank Fill Port.
5. Reinstall fill port cap.
Filling the Rinse Tank
Rear Fill Assembly
(Located behind rear left-hand wheel)
-Typical View
• Solution
Tank Fill Port
• Solution Tank
Fill Valve
Summary of Contents for STS 10