4-2
SECTION 4 –
ENGINE AND DRIVE SYSTEMS
up period before engaging the starter).
NOTE: Ensure that there are no other
warnings before proceeding.
3. Engage the starter.
(If the engine fails to start after 15
seconds, turn the key OFF, wait one
minute, and repeat the procedure. If
the engine does not start after three
attempts, check the fuel supply sys-
tem).
NOTE: Absence of blue or white exhaust
smoke while cranking indicates that
no fuel is being delivered.
4. Observe warning lights on the Machine
Display (after start-up).
NOTE: If any functions do not operate, shut
the engine OFF and determine
cause.
5. Allow a warm-up period of at least five
(5) minutes before operating the engine
at a high RPM.
NOTE: The engine must reach operating
temperature and oil pressure must
stabilize in the normal operating
range before it is run faster than idle
speed (1,000 RPM or less).
6. Disengage the parking brake.
Jump Starting
1. Engage the parking brake.
2. Rotate the Battery Disconnect Switch
(located on the rear mainframe) to the
ON position.
3. Remove caps from the Auxiliary Battery
Charging Posts (located on the rear
mainframe).
4. Connect cables from charging device
(i.e. battery charger or another machine)
to the Auxiliary Battery Charging Posts -
positive cable to the positive terminal,
and negative cable to the negative termi-
nal.
5. Allow batteries to charge approximately
5-10 minutes.
NOTICE
Do not over-crank the starter. Failure to
comply may result in starter damage.
Battery Disconnect Switch
(Located on the rear mainframe)
-Typical View
Auxiliary Battery Charging Posts
(Located on the rear mainframe)
-Typical View
Summary of Contents for STS 10