3-45
SECTION 3 –
CAB
•
On the “Select Action to Program”
screen, select the setting in which you
wish to operate the End Row Manage-
ment Switch (located on the Hydrostatic
Drive Control Handle) - “Single Press” or
“Press and Hold”.
•
On the “End Row Management Editor”
screen, press the “+” Button and select
desired function (AWS, Auto Steer, Mas-
ter Spray, or NORAC Enable).
•
Press OK.
NOTE: Press the “-” Button to remove
function.
•
Press SET.
Delayed Time and Total Time
(Milliseconds)
Delayed Time
Press the “Delayed Time” display to
adjust the time from when the End Row
Management Switch (located on the
Hydrostatic Drive Control Handle) is pressed
to when the function is engaged.
Total Time
Displays the total time from when the End
Row Management Switch is pressed until
delayed time starts.
Example:
Edit End Row Management Settings
•
On the “Select Action to Program”
screen, press the Edit Settings Button.
•
On the “End Row Management Settings”
screen, press EDIT (next to desired End
Row Management setting).
- Pause Before Activate
- Display When Active
End Row Management Button
(Located on the Settings Page)
Select Action to Program Screen
Delayed
Time
Total
Time
Time from when
ERM Button is
pressed to
engagement
1.
0
0
0
2.
500
0
500
3.
1,000
500
1,500
4.
0
1,500
1,500
End Row Management Editor Screen
Summary of Contents for STS 10