![Hagie 60' HsTB 24-Row Operator'S Manual Download Page 26](http://html1.mh-extra.com/html/hagie/60-hstb-24-row/60-hstb-24-row_operators-manual_578961026.webp)
SECTION 3 –
OPERATING YOUR NTB
3-9
NTB Override Timer
The override timer controls how long the
outer sections raise with the transom during
Float operation.
1. Press the NTB Setup Button (located on
the Machine Display Settings Page).
2. On the “NTB Adjustments” screen, press
EDIT (next to NTB Override Timer).
3. Enter desired value (ranging from 100 to
10,000 milliseconds), then press OK.
4. Press OK.
APPLICATION
The solution system is a constantly
monitored, continuously adjusted computer-
controlled system. The cab-mounted digital
spray system console receives information
from various inputs to help determine gallons
per minute (GPM)/liters per minute (l/min)
and gallons per acre (GPA)/liters per hectare
(l/ha).
NOTE: The spray system console must be
programmed for NTB use before
operating.
The following information refers to
components of the solution system and is not
intended to replace the manufacturer’s
operating instructions. Please read and
understand the information provided in this
manual, as well as your machine operator’s
manual and spray system console
manufacturer’s operation manual before
operating.
Refer to the operator’s manual of the
machine being used to operate the NTB for
information on the following:
•
Solution System
•
Rinse System
•
Foam Marker System
NTB Application
1. Calibrate the Spray System Console
(refer to the manufacturer’s operation
manual for calibration instructions).
2. Ensure there is adequate amount of solu-
tion in the tank.
3. Engage the parking brake.
NTB Setup Button
(Located on the Machine Display
Settings Page)
NTB Adjustments Screen
NOTICE
Never attempt to operate the spray
system without solution in the tank.
Failure to comply will result in severe
equipment damage and will void the
warranty.
Summary of Contents for 60' HsTB 24-Row