Page 2 of 8

2916P Proximity Keypad

Installation Instructions

I-EA00130

Rev 6, Rev Date: 5/29/19

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

Test your new user

Present your card or enter an authorized PIN code + #. The green indicator should 
illuminate and the main relay should activate, unlocking  the door for 5 seconds.

Fig. 2 Wiring Pigtail Color Code

}

AUXILIARY RELAY

2 AMPS @ 28VDC MAX

NO

COM

ORANGE

WHITE

BLACK

NC

TO POWER SUPPLY

KEYPAD POWER

12 or 24 VOLTS

AC OR DC

}

+

-

RED

BLACK

MAIN RELAY

5 AMPS @ 28VDC MAX

}

NO

COM

NC

ORANGE

WHITE

YELLOW

Set default parameters (first time use)

Step 1. Enter:  

#9#  123456#

               Enter programming mode (default master code=123456)

Step 2. Enter: 

 03#  4# 

                                    Set the entry code length to 4 digits

Step 3. Enter:  

21# 5#

                                      Set the main relay activation time for 5 sec.

Step 4. Enter:  

       #  

                                      Exit programming mode

**

Assign a user  (PIN only)

Step 1. Enter:  

#9#  123456#    

                      Enter programming mode (default master code)

Step 2. Enter:  

01#  003# 2580# 2580# 1#    

 Assign User 003 with a PIN code of 

‘2580’. 

                                                                        Activate the main relay when entered.   

Step 3. Repeat Step 2 to enter another unique user & PIN or continue to Step 4.

Step 4. Enter:  

       #  

                                     Exit programming mode

**

Deleting a  user code

Step 1. Enter:  

#9#  123456#

                 Enter programming mode (default master code)

 
Step 2. Enter:  

02#  002# 002# 

                         User 002 has been deleted. 

Step 3. Enter:  

       #  

                                        Exit programming mode

**

QuickStart  Programming

You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the  2916P is 
in programming mode. Use the option codes to program each function.   After the new data entry is complete for each function , 
the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the programming has 
been accepted.  The red indicator will light if any programming data is entered incorrectly or the function is rejected. If a red 
indicator is seen, the entire function (option code + data)  will have to be fully re-entered.  The keypad will remain in programming 
mode until        # is pressed or after 30 seconds of inactivity.

**

KEYPAD
POWER

WIRE
HARNESS
(E1-E8)

MAIN
RELAY

AUXILIARY
RELAY

ANTI-TAMPER
SWITCH

BACK

JP1

E1

E8

JP2

Grn Wire
To earth ground

BLACK

PINK/SALMON

GREEN

GRAY

BLACK

VIOLET

BLACK

BLUE

 DOOR POSITION 

SWITCH

[N/C]

REQUEST-TO-EXIT 

SWITCH

[N/O]

GROUND

OUTPUT #4

OUTPUT #3

GROUND

SENSE

REQUEST TO EXIT

GROUND

E

1

E

8

E

7

E

6

E

5

E

4

E

3

E

2

C

NO

C

NC

NO

AUXILIARY OUTPUTS

100mA MAX TO COMMON

{

*

*

NOT USED

CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

!

!

RED/GREEN
POWER/ACCESS/ERROR
INDICATOR

YELLOW

PROGRAM

INDICATOR

KEYPAD

FRONT

PROX 

Antenna

Assign a user  (Card only)

Step 1. Enter:  

#9#  123456#    

                      Enter programming mode (default master code)

Step 2. Enter:  

06#  002# 9876# 9876# 1# (Present card) 

        Assign card to User 002 with a

                                                                                                     PIN code of 

‘9876’. 

Activate

                                                                                                     the main relay when validated.

  

Step 3. Repeat Step 2 to enter another unique user & card, or continue to Step 4.

Step 4. Enter:  

       #  

                                     Exit programming mode.

**

Summary of Contents for 2916P

Page 1: ...nhibit the input can be wired to a normally open service switch or automatic timer that will disable access while the switch is closed The REQUEST TO EXIT input can be wired to a normally open pushbut...

Page 2: ...ust first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 2916P is in programming mode Use the option codes to program each function After the ne...

Page 3: ...4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE EXAMPLE 2 BLUE PINK SALMON OUTPUT 3 COM OUTPUT 4 COM POWER SOURCE OUTPUT 3 END OF LINE RESISTOR ALARM PANEL NO ZONE COMMON LOW VOLTAGE LAMP BLACK BLACK OUT...

Page 4: ...Relay 2 Auxiliary Relay 3 Both Relays 10 Relay 1 toggled 20 Relay 2 toggled 30 both Relays toggled 12 Relay 1 toggled Relay 2 timed open 21 Relay 1 timed open Relay 2 toggled The yellow indicator will...

Page 5: ...4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Lockout Disable Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this ou...

Page 6: ...Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets t...

Page 7: ...Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X...

Page 8: ...Rev 6 Rev Date 5 29 19 Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 OPTIONAL SHROUD SURFACE MOUNT WITH OPTION...

Reviews: