Beep Sounds During Auxiliary Relay Default: No
Selects whether or not the keypad beeps during Auxiliary Relay
activation.
Press: 42 #
Sound
#
Sound=1 for Yes, =0 for No
Beep Sounds During Output #3 Default: No
Selects whether or not the keypad beeps during Output #3
activation.
Press: 43 #
Sound
#
Sound=1 for Yes, =0 for No
Beep Sounds During Output #4 Default: No
Selects whether or not the keypad beeps during Output #4
activation.
Press: 44 #
Sound
#
Sound=1 for Yes, =0 for No
Anti-Pass Back Time
Default: No Anti-Pass Back
Sets the length of time an entry code will not function after it is
used.
Press: 51 # Minutes
#
Minutes=Time in minutes (2-4), 0=No Anti-passback
RESETTING KEYPAD
Master Reset
CAUTION: Performing a master reset will clear the entire
memory of the 2916P and return all programmable options
to the factory default values. ALL ENTRY CODES WILL BE
ERASED. NOTE: The Master Code will NOT be reset.
STEP 1
Disconnect power from the keypad.
STEP 2
Press and hold down the * and # keys.
STEP 3
Apply power to the keypad, continue holding the keys
down until the red indicator starts flashing
STEP 4
Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the
yellow indicator will go out.
Resetting the Master Code
STEP 1
Remove the 2916P from the wall and disconnect
power from the keypad.
STEP 2
Locate & Remove jumper at JP2. Reference page 2.
STEP 3
Re-apply power. You will get a single beep and
the yellow LED will flash momentarily.
STEP 4
Replace jumper on JP2.
THE MASTER PROGRAMMING CODE IS NOW 123456.
Beep Sounds During Main Relay Default: No
Selects whether or not the keypad beeps during Main Relay
activation.
Press: 41 #
Sound
#
Sound=1 for Yes, =0 for No
Solid-state Output #4 On-time Default: 02 Seconds
Sets the length of time Output #4 activates when triggered.
Press: 24 #
Seconds
#
Seconds=Output time in seconds (1-60), 99=Toggle Mode
Beep Sounds on Keystrokes Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press: 40 #
Sound
#
Sound=1 for Yes, =0 for No
Selects mode for Keypad LED Backlight Default: 30 Sec
Selects whether or not the keypad back light stays OFF, lights for
30 seconds when activated or stays ON.
Press: 52 # Output
#
0 = Light always OFF
1 = 30 sec light when activated (default)
2 = Light always ON
Solid-state Output #3 On-time Default: 02 Seconds
Sets the length of time Output #3 activates when triggered.
Press: 23 #
Seconds
#
Seconds=Output time in seconds (1-60), 99=Toggle Mode
Beep Sounds Anti-Tamper Activation Default: No
Selects whether or not the keypad beeps during Anti-Tamper
switch activation.
Press: 45 #
Sound
#
Sound=1 for Yes, =0 for No
Changing the
Beeper Sound Level
The Keypad
’
s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.
Changing the 6-Digit Master Programming Code
Press: 98 #
Master
Code
#
Master Code
#
Master Code=The new 6-digit Master Programming Code
Keypad Lockout Count Default: 3 Attempts
Sets the number or incorrect entry code attempts allowed
before the keypad
“
locks out
”
for 60 seconds.
Press: 50 # Attempts
#
Attempts=Number of attempts before lockout (2-7)
*Refer to Option 13 to Enable Lockout Feature
Door Ajar Timer Default: 60 Seconds
Sets the amount of time the door may be held open after an
authorized access. The DOOR AJAR output will activate after the
time expires.
Press: 25 #
Seconds
#
Seconds=Held open time in seconds (1-60)
Auxiliary Relay On-time
Default: 02 Seconds
Sets the length of time the Auxiliary Relay activates when
triggered.
Press: 22 #
Seconds
#
Seconds=Output time in seconds (1-60)