background image

Page 5 of 8

2916P Proximity Keypad

Installation Instructions

I-EA00130

Rev 6, Rev Date: 5/29/19

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

Configure Sense Input                                   Default:  INHIBIT 

  

The Sense Input (gray wire) can be programmed for either 
DOOR SENSE or INHIBIT.

Press:  10 # Input #

Input=0 for Door Sense; =1 for Inhibit

When programmed for DOOR SENSE, if an open condition on 
the input occurs before access is granted (with an entry code or 
with the request-to-enter input) a FORCED ENTRY output will 
occur.  If an open condition remains 60 seconds after a relay 
activation for access, a DOOR AJAR output will occur.  

When programmed for INHIBIT, a closed condition on the input 
will prevent Relay #1 from activating when access is requested 
with an entry code.  This mode is typically used with an external 
timer to disable the access device at certain times.

Select Forced Entry Output

           Default:  No Output

  

Sets which output activates if the DOOR SENSE input opens 
before access is granted.  This output is timed and configured 
by the relay 

On-time

”.

Press:  11 # Output #

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

0=No Output

Select Door Ajar Output

           Default:  No Output

  

Sets which output activates if the DOOR SENSE input stays open 
60 seconds after access is granted (door ajar time is adjustable 
using Function 25).  This output is not timed.

Press:  12 # Output #

Output=Output to Activate (0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

0=No Output

Select Keypad Active Output

 Default:  No Output

Sets which output activates when any keys are pressed.  This 
output is timed.  If toggle mode is selected for the output, the timer 
value defaults to 2 seconds.

Press: 14 # 

Output

 

 #  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

Select Keypad Lockout Output

           Default:  No Output

Sets which output activates when the keypad is 

locked out

” 

after 

too many incorrect entry code attempts. The lockout time is 60 
seconds.

Press: 13

 

 # 

Output

 

 #  

Output=Output to Activate (0-4)

1=Main Relay;  2 = Auxiliary Relay;  3=Output #3; 4=Output #4;  

0=No Output / Lockout Disable

Select Alarm Shunt Output

 Default:  No Output

Sets which output activates during the time access is granted.  
(Use this output ot shunt alarm contacts attached to the access 
door.)  This output may be timed or toggled.

Press: 15 # 

Output

 

 #  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

Select Request-to-Exit Output

 

Default:  No Output

Sets which output activates when the Request-to-Exit input is 
grounded.  This output may be timed or toggled.

Press: 16 # 

Output

 

 #  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

REX input terminates toggle of Main or Aux. Relay

Main Relay On-time

           Default:  02 Seconds

Sets the length of time the Main Relay activates when triggered.

Green LED is on when Main Relay is active.

Press: 21 # 

Seconds

 

 #  

Seconds=Output time in seconds (1-60)

Anti-Tamper Output

 

              Default:  No Output

Sets which output activates when the Anti Tamper switch on the 
back of the keypad is activated. 

Press: 17 # 

Output

 

 #  

Output=Output to Activate(0-4)

0=No Output;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

Erasing All Entry Codes

WARNING:  PERFORMING THIS COMMAND WILL REMOVE 

ALL ENTRY CODES FROM THE MEMORY

Press: 97 # 0 0 0 0 0 0

 

 #  0 0 0 0 0 0

 

 #  

  

Note: 

The green indicator will light while the memory is being 

erased.  This may take up to 15 seconds.

Erasing Multiple Users (Sequential)

Press: 09 # 1

st

 

User

 

 # Number of users

 

 #  

1

st

 User =Starting user number to delete

Number of users = Total number of consecutive users  to delete

The yellow indicator will flash quickly while the 2916P erases the 
user from  memory.  The green indicator will light when the code 
is erased.

Erasing a Single User

Press: 02 # 

User

 

 #  

User

 

 #  

User =The user number to delete  001-500

The yellow indicator will flash quickly while the 2916P erases the 
user from memory.  The green indicator will light when the code is 
erased.

Changing a User PIN

Press: 04 # 

User

 # New Code

 

 #  New Code

 

 #  

User =The user number whose PIN will be changed

See the following example that sets entry codes 1234 for normal 
operation and 5678 for toggle operation.

Press:  01 # User # 1 2 3 4 # 1 2 3 4 # 1 #

01=Programming Step;  1234=Entry Code;  1=Main Relay

Press:  01 # User # 5 6 7 8 # 5 6 7 8 # 20 #

01=Program Step;  5678=Entry Code;  20=Auxiliary Relay toggle

Summary of Contents for 2916P

Page 1: ...nhibit the input can be wired to a normally open service switch or automatic timer that will disable access while the switch is closed The REQUEST TO EXIT input can be wired to a normally open pushbut...

Page 2: ...ust first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 2916P is in programming mode Use the option codes to program each function After the ne...

Page 3: ...4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE EXAMPLE 2 BLUE PINK SALMON OUTPUT 3 COM OUTPUT 4 COM POWER SOURCE OUTPUT 3 END OF LINE RESISTOR ALARM PANEL NO ZONE COMMON LOW VOLTAGE LAMP BLACK BLACK OUT...

Page 4: ...Relay 2 Auxiliary Relay 3 Both Relays 10 Relay 1 toggled 20 Relay 2 toggled 30 both Relays toggled 12 Relay 1 toggled Relay 2 timed open 21 Relay 1 timed open Relay 2 toggled The yellow indicator will...

Page 5: ...4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Lockout Disable Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this ou...

Page 6: ...Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets t...

Page 7: ...Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X...

Page 8: ...Rev 6 Rev Date 5 29 19 Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 OPTIONAL SHROUD SURFACE MOUNT WITH OPTION...

Reviews: