Remedy 

 

 

Problem* 

Unit 

Cause 

Remedy 

Unit cannot be switched on 

Electric trolley 

No main power 

Check connection to mains supply

 

Phase sequence not correct (with low voltage control) 

Exchange 2 phases 

(see wiring note at the plug) 

Motor runs in opposite direction  

Electric trolley 

Phase sequence / rotating field wrong 

(with three-phase direct control) 

Exchange 2 phases 

(see wiring note at the plug)

 

Motor does not run

 

Electric trolley 

Fuse burnt out

 

Replace the fuse

 

Defective switching unit in the control button switch

 

Replace the switching unit

 

Interruption in the control cable

 

Check control cable and replace if necessary.

 

Defect of capacitor (only for one-phase alternating 

current) 

Replace the capacitor 

Overheat protection has tripped* 

Allow engine to cool 

Defective coil - mechanic or electric overload

 

Motor must be repaired by a specialist 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Pneumatic 

trolley 

Operation pressure / quantity of air is too low 

Check connection to mains supply 

After prolonged standstill 

See maintenance - pneumatic motor 

Motor runs – trolley does not move

 

Motor driven 

trolley 

No or incorrect power transmission 

Check driving pinion and repair if necessary, 

check condition of trolley wheels / contact to main 

beam surface and repair / adjust if necessary 

If the unit is suitable for explosive atmospheres, please 
clarify with the manufacturer what to do!*

 

Motor hums and uses excessive current 

 

Electric trolley 

Defective coil

 

Motor must be repaired by a specialist 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Rotor is rubbing

 

(Optional) brake does not release

 

See problem “(Optional) brake does not release”

 

Defect of capacitor 

(only for one-phase alternating current) 

Replace the capacitor 

Defect of starter relay 

(only for one-phase alternating current) 

Replace the starter relay 

Phase failure (only three-phase direct control) 

Find the cause and repair 

Motor does not brake or has excessive afterrunning.

 

Electric trolley 

Switching error after intervention in the electric circuit

 

Check the electric connection of the brake acc. to 

the wiring diagram 

Motor driven 

trolley 

Brake linings are worn or dirty.

 

Brake lining carrier must be changed completely 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Air gap is too large

 

Re-adjust the air gap 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

(Optional) brake does not release

 

Electric trolley 

Brake rectifier defective

 

Replace the brake rectifier 

If the unit is suitable for explosive atmospheres, the 

motor must be returned to the manufacturer for repair!*

 

Brake current relay defective

 

Replace the brake current relay 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Brake coil is defective 

Replace the brake coil 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Permissibe air gap is exceeded due to worn out brake 

lining

 

Re-adjust the air gap and exchange the brake lining 

if necessary 

If the unit is suitable for explosive atmospheres, the 

motor must be returned to the manufacturer for repair!*

 

Power drop in the mains power line > 10%

 

Provide correct power supply voltage

 

Pneumatic 

trolley 

Operation pressure / quantity of air is too low 

Check connection to mains supply 

Fuses burnt out or motor contactor is triggered

 

Electric trolley 

Short circuit in component

 

Eliminate the short circuit

 

Motor has a short circuit in the body or windings

 

Correct the problem by a specialist 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Motor is switched incorrectly

 

Correct the switching

 

Wrong type of fuse

 

Replace the fuse with correct one

 

Trolley runs very slowly or not at all 

All trolleys 

Driving pinion dirty or blocked. 

Clean the driving pinion and lubricate it, if necessary, 

exchange worn parts 

Hand geared 

trolley 

Hand chain is twisted or blocked 

Place the hand chain correctly 

*) as far as applicable 

 

 

17 

Decommissioning 

 

 

   

WARNING!

 

It is essential that the following points are observed in order to prevent damage to the equipment or critical 
injury when the device is being decommissioned: 

 

 

 

It is mandatory that all steps for decommissioning the machine are carried out in the indicated sequence: 

  First secure the working area for decommissioning, leaving plenty of space. 

  Read the chapter "Safety instructions". 

  Disassembly is carried out in reverse order to the assembly.  

  Please make sure that all operating material is disposed of in accordance with environmental regulations. 

Summary of Contents for 22/90

Page 1: ...Rev 06 5 52 653 00 01 06 Monorail Trolley 19 90 22 90 push travel trolley 19 90 hand geared trolley 22 90 electric trolley 22 90 E Installation Operating and Maintenance Instructions...

Page 2: ...mation 3 2 Safety 3 2 1 Warning notice and symbols 3 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 4 2 5 Basic safety measures 5 3 Transport and St...

Page 3: ...efore delivery all products are packed properly Check the goods after receipt for any damage caused during transport Report any damage immediately to the forwarding agent This manual allows a safe and...

Page 4: ...ctional condition and the safety components in particular are checked regularly to ensure that it is functioning properly The required personal protective equipment for the operators service and repai...

Page 5: ...the load Only use the hoists appropriately The equipment is to be used exclusively for movement of goods Under no circumstances my persons be moved Never load the devices beyond their working load lim...

Page 6: ...sible installed in a covered room If they are used in the open protect the units against the effects of weather such as rain hail snow direct sunshine dust etc we recommend to use a cover in parking p...

Page 7: ...ectric trolley 16 4 m min Weights Type bolt Size 500 kg 1 t 1 5 t 2 t 2 5 t 3 2 t 5 t 6 3 t 19 90 N1 4 1 6 8 7 8 7 8 16 6 16 6 31 5 31 5 N2 4 5 8 5 9 9 9 9 19 9 19 9 39 4 39 22 90 N1 5 4 8 1 9 2 10 9...

Page 8: ...uated on the load bars 2 of the trolley Dimension X is set by placing washers 6 from the outer to the inner side X increases or from the inner to the outer side X decreases Washers 6 and rubber discs...

Page 9: ...2 3 mm 1 1 5 mm each side bigger and for trolleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam 6 4 Tools 7 Control Only people that are familiar with the operatio...

Page 10: ...bserve the duty cycle i e intermittent operation S3 40 ED as per VDE 0530 means that in a period of 10 minutes the motor can operate no matter the height of the load for 4 minutes It is therefore irre...

Page 11: ...nnection The technical dates of the motors are to be taken from the type plates The wiring diagram is situated in the terminal box Select connection cross sections as per VDE 0100 Put sleeves on the e...

Page 12: ...ing 1 into the shaft slot 2 Insert the feather key 2 into the motor shaft 3 Fix hub 3 with retaining ring 1 4 Assemble the friction plate 4 if existent 5 Push the rotor 5 onto the hub 3 6 Lock the mag...

Page 13: ...sufficient to keep the cooling airways clean and monitor the roller bearing and its lubrication status A high temperature fat must be used if the roller bearing is replaced CAUTION Brake linings and s...

Page 14: ...be changed completely If the unit is suitable for explosive atmospheres the motor must be returned to the manufacturer for repair Air gap is too large Re adjust the air gap If the unit is suitable fo...

Page 15: ...the equipment and any materials it contains is carried out in accordance with environmental regulations 18 Additional documents 18 1 Electric wiring diagrams Electric wiring diagrams are attached to...

Reviews: