![background image](http://html1.mh-extra.com/html/habitat-et-jardin/duo/duo_installation-and-directions-for-use_3135083008.webp)
- 7 -
Jets
Touch the “Jets” button once to activate the low speed of the pump and again for the high speed. Press the
“Jets” button again to turn off the pump. If left running, the low speed of the pump will automatically turn
off after 4 hours, and the high speed will automatically turn off after 15 minutes. The low speed of the pump
runs when when the blower is on. It may also activate for at least 2 minutes every 30 minutes to detect the
spa temperature and then to heat to the set temperature if needed, depending upon mode. When the low
speed turns on automatically, it cannot be deactivated from the panel; however, the high speed may be
started.
Light
Press the “Light” button to turn the light on and off. If left on, the light automatically turns off after 4 hours.
Mode
Mode is changed by pressing the “Temp” or “Set” button, then pressing the “Light” button.
Standard Mode
is programmed to maintain the desired temperature. Note that the last measured spa
temperature displayed is current only when the pump has been running for at least 2 minutes. “
” will be displayed momentarily when you switch into Standard Mode.
Economy Mode
heats the spa to the set temperature only during filter cycles. “
” will display solid when temperature is not current, and will alternate with temperature when temperature is
current.
Sleep Mode
heats the spa to within 20°F/10°C of the set temperature only during filter cycles. “
” will display solid when temperature is not current, and will alternate with temperature when temperature is
current.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is energized. The second filter cycle begins 12 hours later.
Filter duration is programmable for 2, 4, 6, 8 hours or for continuous filtration (indicated by “
” The default filter time is 2 hours. To program, press “Temp” or “Set,” then “Jets.” Press “Temp” or “Set”
to adjust. Press “Jets” to exit programming. The blower purges for 30 seconds at the beginning of each filter
cycle. The low speed of the pump runs during filtration and the ozone generator (if installed) will be
enabled.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C within the heater, the pump and blower will
automatically activate to provide freeze protection. The equipment stays on until 4 minutes after the sensors
detect that the spa temperature has risen to 45°F/7.2°C or higher. In colder climates, an optional additional
freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard
sensors. Aux freeze sensor protection acts similarly except with the temperature thresholds determined by
the switch and without a 4-minute delay in turnoff. See your dealer for details.enabled.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C within the heater, the pump and blower will
automatically activate to provide freeze protection. The equipment stays on until 4 minutes after the sensors
detect that the spa temperature has risen to 45°F/7.2°C or higher. In colder climates, an optional additional
freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard
sensors. Aux freeze sensor protection acts similarly except with the temperature thresholds determined by
the switch and without a 4-minute delay in turnoff. See your dealer for details.