background image

 

- 3 - 

Ⅱ、

Control system usage instructions

   

 

(

-1)

USA BALBOA control system :model GS523 or GS510 

 

GS523DZ (for three SPA massage pumps) 

 

1. First Start-up 
Your spa will enter Priming Mode (Pr

when it is energized. During Priming Mode, press “Jets” button (s) 

repeatedly and be sure all pumps are free of air. Priming Mode lasts for less than 5 minutes. Press “Warm" 
or “Cool" to exit. After Priming Mode, the spa will run in Standard Mode (see Mode section). 
The pump responsible for heating and filtration (pump 1 low-speed on non-circ system, or the circ pump on 
circ systems) will be referred to simply as the pump. In multi-button sequences, if the buttons are pressed 
too quickly in sequence, they may not register. 
Pump is the abbreviation of those used for heating and filtering. on operation, if you press too quickly, it 
may be unavailable. 
 
2. Temp control (80°F-104°/26.0°-40.0°C) 
The last measured water temperature is constantly displayed. The water temperature displayed is current 
only when the pump has been running for at least 2 minutes. To display the set temperature, press “Warm" 
or “Cool" once. To change the set temperature, press a temperature button again before the display stops 
flashing. After three seconds, the display will stop flashing and begin to display the current Spa temperature. 
 
3. Jets 1: (

extend 

key) 

This key is without control any function and pump, this key is excrescent or uses it to extend other function 
if you need. 
 
4. Jets 2/ Jets 3/Blower

if equipped

 

Press the “Jet2” button once, pump 1 would be turn on; Press the “Jet2” button twice, pump2 would be turn 
on, pump1 still operated; Press the “Jet2” button thrice, pump 1 would be turn off, pump2 still operated; 
Press the “Jet2” button quartic, pump2 would be turn off . 
 
5. Light 
Press “Light” to operate the spa light. And off after 4 hours. 
 
6. Time set 
When SPA gets through with electricity for the first time,” SET TIME" will be shown on control panel. 
Press "time" first, then "Mode/Prog" later, press "Warm" or "Cool", when pressing "Warm" or "Cool", time 
set will be added or deducted by 1 minute finally, press "time" again to make sure you have set time. 
 
7. .Mode 
(1) Mode is changed by pressing “Warm” or “Cool”, then pressing “Mode” for change. 
(2)Standard Mode maintains set temperature, and it will be displayed momentarily when you switch into 
Standard Mode. (3)Economy Mode heats the spa to the set temperature only during filter cycles. Ecn will 
display when water temp is not current, and will alternate with water temp when the pump is running. 

Summary of Contents for Duo

Page 1: ...EN SPA 908 M3301 M3303 M3332 M3351 M3360 M3369 M3372 3319 Installation and Directions of Use...

Page 2: ...III Troubleshooting page13 IX Warranty process page14 FR SAV INFORMATION VIDEO CONTACT EN AFTER SALES SERVICE INFORMATION VIDEO CONTACT DE REPARATUR SERVICE UND ERSATZTEILE INFORMATIONEN VIDEO KONTAKT...

Page 3: ...ike drugs must be walled within filter bag 13 After finishing strenuous exercise please do not use the SPA right away 14 If feeling unwell when or after you used the SPA please stop it right away and...

Page 4: ...n again before the display stops flashing After three seconds the display will stop flashing and begin to display the current Spa temperature 3 Jets 1 extend key This key is without control any functi...

Page 5: ...conds then press Mode Prog again and SET START FILTER1 AM will show on panel Press Warm or Cool to reset the beginning and ending time of filter cycle When pressing Mode Prog you will see SET START FI...

Page 6: ...HFL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all the pumps have been primed If the problem stil...

Page 7: ...st for less than 5 minutes press Temp or Set to skip Priming Mode and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode Temp Set 80 F 104 F 26 C 40 C The...

Page 8: ...ns 6 minutes after the spa is energized The second filter cycle begins 12 hours later Filter duration is programmable for 2 4 6 8 hours or for continuous filtration indicated by The default filter tim...

Page 9: ...a cover and allow water to cool Once the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE...

Page 10: ...20 40pieces some of the models could be equiped with fountain and waterfall function some could choose to install TV and DVD some could choose to install aromatic perfume ect Description on Using Par...

Page 11: ...onnecting to the 3 5mm voice frequency extension cord 5 If one Smartphone or flat computer have connected to the bluetooth player other Smartphone or flat computer cannot connect to this bluetooth pla...

Page 12: ...ET 2 PULL OUT THE FILTRATION TUCK NET 3 MATCH THE PAPER CORE CORRECTLY INSIDE AND SCREW DOWN IT IN SEQUENCE THEN PUT THE COVER OF FILTRATION BUCKET ON TOP Type three 1 use the key to open the service...

Page 13: ...at least 3 6mm2 to connect to SPA power for big swimming spa reserve at least two group of wire for at least 3 6mm2 if customer need for 380V please reserve the leakage for 380V and power supply for a...

Page 14: ...Remove the water return unit and nozzle for cleaning and removing dirt 5 Do not frequently wipe the gold and chrome plated parts do not contact it with organic solvent 6 please keep blunt and knife aw...

Page 15: ...this case please stop using filter to remove it and clean the core store it in safe place or move the filter core to interior Or keep the SPA at standby state Troubleshooting Faults Reason Solution N...

Page 16: ...l one of the Balboa tech service departments to get assistance in troubleshooting the product and diagnose the problem In Europe Balboa warranty department can be reached at HYDROAIR INTERNATIONAL BAL...