background image

 

- 14 -
 

pump, after replacing the pump, install power wire, fix the bolts, put into small amount of water into the 
bathtub, check if there’s leakage at the pump, and then install the side plate of the bathtub.   
2). Replace the filter water pump: cut off power supply, open the bathtub side plate, turn off the valves on 
both ends of water pump, remove the wires and open the water pump, loosen the fixed bolts and take out the 
water pump, after replacing the pump, install power wire, fix the bolts, put into small amount of water into 
the bathtub, turn on the valve, check if there’s leakage at the pump, and then install the side plate of the 
bathtub. 
3). Replace the thermostat: cut off power supply, open the bathtub side plate, turn off the valves on both 
ends of thermostat, remove the wires, loosen the fixed bolts and take out the thermostat, after replacement, 
install power wire, fix the bolts, put into small amount of water into the bathtub, turn on the valve, check if 
there’s leakage at the pump, and then install the side plate of the bathtub.   
4). Replace the filter core: cut off power supply, open the bathtub side plate, turn off the valves, loosen the 
bolts on top of the filter, take out the filter, remove dirt on bottom of the filter.   
5). Anti-frozen of filter: In some area, water may be frozen in winter, under this case, please stop using filter, 
to remove it and clean the core, store it in safe place or move the filter core to interior. Or keep the SPA at 
standby state. 
 
 

. Troubleshooting: 

   

Faults   

Reason   

Solution   

No reaction for panel 
key 

1.

 

Panel was locked 

2.

 

Panel is broken 

Unlock the panel 
Change panel 

No power supply   

1. There’s problem for the power 
circuit;   
2. Protective switch is cut off.   

Check the circuit   
Check and remove short circuit, conenct 
the protective switch   

Nozzle doesn’t spray 
water   

1. There’s problem for power 
supply of water pump;   
2. Water pump is not started.   
3. Massage water pump is 
damaged   
4. There is air in pipe 

Check and connect the power wire;   
Check the massage water pump   
Replace the massage water pump     
Purify pipe by taking the loose joint part   

Underwater lamp 
doesn’t light on   

1. Bulb is damaged;   
2. Fuse is broken.   

Replace the bulb   
Replace the fuse   

Poor filtering effect   

1. Filter water pump is not started; 
2. Filter isn’t cleaned; 
3. Filter water pump is damaged.   

Start the filter water pump   
Clean the filter   
Replace the filter water pump     

Constant temperature 
effect is unavailable   

1. Thermostat is damaged;   
2. Power supply is unavailable.   
3. Filter is jammed.   

Repair or replace the thermostat     
Check the power supply   
Clean or replace the filter paper core   

Bathtub is scratched   

 

Grind with 2000# grinding paper with 
water, and then polish with toothpaste 
and soft fabric 

NOTICE: the usage manual is only for reference, and all data subject to the actual product, any 

update without notice.     

 

 

 

Summary of Contents for Duo

Page 1: ...EN SPA 908 M3301 M3303 M3332 M3351 M3360 M3369 M3372 3319 Installation and Directions of Use...

Page 2: ...III Troubleshooting page13 IX Warranty process page14 FR SAV INFORMATION VIDEO CONTACT EN AFTER SALES SERVICE INFORMATION VIDEO CONTACT DE REPARATUR SERVICE UND ERSATZTEILE INFORMATIONEN VIDEO KONTAKT...

Page 3: ...ike drugs must be walled within filter bag 13 After finishing strenuous exercise please do not use the SPA right away 14 If feeling unwell when or after you used the SPA please stop it right away and...

Page 4: ...n again before the display stops flashing After three seconds the display will stop flashing and begin to display the current Spa temperature 3 Jets 1 extend key This key is without control any functi...

Page 5: ...conds then press Mode Prog again and SET START FILTER1 AM will show on panel Press Warm or Cool to reset the beginning and ending time of filter cycle When pressing Mode Prog you will see SET START FI...

Page 6: ...HFL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all the pumps have been primed If the problem stil...

Page 7: ...st for less than 5 minutes press Temp or Set to skip Priming Mode and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode Temp Set 80 F 104 F 26 C 40 C The...

Page 8: ...ns 6 minutes after the spa is energized The second filter cycle begins 12 hours later Filter duration is programmable for 2 4 6 8 hours or for continuous filtration indicated by The default filter tim...

Page 9: ...a cover and allow water to cool Once the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE...

Page 10: ...20 40pieces some of the models could be equiped with fountain and waterfall function some could choose to install TV and DVD some could choose to install aromatic perfume ect Description on Using Par...

Page 11: ...onnecting to the 3 5mm voice frequency extension cord 5 If one Smartphone or flat computer have connected to the bluetooth player other Smartphone or flat computer cannot connect to this bluetooth pla...

Page 12: ...ET 2 PULL OUT THE FILTRATION TUCK NET 3 MATCH THE PAPER CORE CORRECTLY INSIDE AND SCREW DOWN IT IN SEQUENCE THEN PUT THE COVER OF FILTRATION BUCKET ON TOP Type three 1 use the key to open the service...

Page 13: ...at least 3 6mm2 to connect to SPA power for big swimming spa reserve at least two group of wire for at least 3 6mm2 if customer need for 380V please reserve the leakage for 380V and power supply for a...

Page 14: ...Remove the water return unit and nozzle for cleaning and removing dirt 5 Do not frequently wipe the gold and chrome plated parts do not contact it with organic solvent 6 please keep blunt and knife aw...

Page 15: ...this case please stop using filter to remove it and clean the core store it in safe place or move the filter core to interior Or keep the SPA at standby state Troubleshooting Faults Reason Solution N...

Page 16: ...l one of the Balboa tech service departments to get assistance in troubleshooting the product and diagnose the problem In Europe Balboa warranty department can be reached at HYDROAIR INTERNATIONAL BAL...

Reviews: