10-3
Figure10-4 Installing a fan tray
Replacing a FIP module
CAUTION:
•
Do not touch the components on a FIP module directly with your hands.
•
Do not use excessive force during the replacement procedure.
•
For adequate heat dissipation and dust prevention, install a filler panel in a FIP module slot if you
are not to install a new FIP module in the slot after removing the old one.
To remove a FIP module during device operation, first press the remove button for over 0.5 seconds.
You can remove the FIP module only after the remove LED is off.
To remove a FIP module:
1.
Wear an ESD wrist strap. Make sure the wrist strap makes good skin contact and is reliably
grounded.
2.
Remove all cables from the module.
3.
As shown in
, holding the ejector lever of the FIP module with one hand and pressing
down the red latch on the ejector lever, pull the FIP module part way out of the slot. Supporting
the FIP module bottom with the other, pull the module completely out of the slot.
4.
Place the removed FIP module on an antistatic mat.
5.
Install a new FIP module. For the installation procedure, see "
If you are not to install a new FIP module, install a filler panel in the slot.