5-2
4.
Open the ejector levers on the MIC-X interface card and push the MIC-X interface card slowly
into the slot along the guide rails.
5.
Close the ejector levers until the MIC-X interface card is securely seated in the slot.
6.
Use a Phillips screwdriver to fasten the captive screws on the MIC-X interface card.
Figure5-2 Installing a MIC-X interface card
7.
Install the FIP with the MIC-X interface card in the target slot on the device. For the installation
procedure, see "
Installing a FIP module
CAUTION:
•
The FIP modules are hot swappable.
•
If you are to install a MIC-X interface card on the device, first install it on a FIP module, and then
install the FIP module with it on the device.
To install a FIP module:
1.
(Optional.) Install MIC-X interface cards on the FIP module. For the MIC-X interface card
installation procedure, see "
Installing MIC-X interface cards
."
2.
Wear an ESD wrist strap and make sure the strap makes good skin contact and is reliably
grounded.
3.
Face the front panel of the device, use a Phillips screwdriver to loosen the captive screws on
the filler panel, and then remove the filler panel.