Displaying the temperature information for the
firewall
Use the
display environment
command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
-------------------------------------------------------------------------------------
--
Slot Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit
Shutdown-UpperLimit
1 inflow 1 37 0 60 65
NA
1 outflow 1 42 0 71 83
NA
1 hotspot 1 71 0 82 92
97
Table5-5 Output description
Field
Description
Sensor
Temperature sensor:
•
inflow
—Air inlet vent temperature sensor.
•
outflow
—Air outlet vent temperature sensor.
•
hotspot
—Hotspot temperature sensor.
Temperature
Current temperature.
LowerLimit
Low temperature alarm threshold.
Warning-UpperLimit
Warning-level high temperature alarm threshold.
Alarm-UpperLimit
Alarm-level high temperature alarm threshold.
Shutdown-UpperLimit
Shutdown-level high temperature alarm threshold. The firewall automatically
powers off when the temperature exceeds this threshold.