Installation Manual
H3C S3100-52P Ethernet Switch
Chapter 1 Product Overview
1-4
LED
Mark
Color
Indicates
POST
running
PWR flashes
green
The POST test ID (in the range 1
to 9).
POST
failed
PWR flashes
yellow
The POST test ID of the failed
test.
Software
downloa
ding
PWR flashes
green
A bar rotates clockwise around the
display.
Fan
failed
PWR stays red
“F”, meaning the FAN fails.
7-
segme
nt
digitron
display
Unit
Unit id
Button
released
UNIT ID in the fabric; and for a
standalone unit, “1”
III. Attributes of the 10Base-T/100Base-TX Ethernet ports
Table 1-3
Attributes of the 10Base-T/100Base-TX Ethernet Ports on the S3100-52P
Attribute
Description
Connector RJ-45
Number of ports
48
Rate
z
10 Mbps, half duplex/full duplex
z
100 Mbps, half-duplex/full duplex
z
MDI/MDI-X auto-sensing
Standard IEEE
802.3u
Transmission segment over the selected
medium
100 m (328.08 ft) over the category-5
unshielded twisted pair (UTP) cable
IV. Console port
The S3100-52P Ethernet switch provides one EIA/TIA-232 compliant Console port for
local or remote switch configuration.
Table 1-4
Console port attributes
Attribute
Description
Connector RJ-45
Standard EIA/TIA-232
Baud rate
9600 bps (default)