Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 3 Installation
3-9
Note:
z
No guide rails are delivered with the device.
z
Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches)
between devices for the purpose of heat dissipation.
3.1.2 Desk Mounting
When a 19-inch standard cabinet is not available, you can simply
place the switch on a clean desk. When doing so, you should ensure
that:
z
The desk is stable and well grounded.
z
A clearance about 10 cm (3.9 in) is reserved around the
switch for heat dissipation.
z
No heavy object is placed on the switch.
z
S3100-SI and S3100-TP-EI-W Series Ethernet Switches are
designed with no fan. Therefore, you should install them in a
drafty environment, and keep at least a vertical distance of
1.5 cm (0.6 in) between devices if you need to stack
switches one upon another.
3.1.3 Wall Mounting
You can mount some models of S3100 Series Ethernet Switches
on concrete walls or wood walls. Table 3-3 lists the models that
support wall mounting.