PC Interface
LT51 User Manual
72
LT51 Commands
CONFIGSETTING
Syntax: <0xAD><Config><Value><xx><xx> (LT51 returns <0x99>)
This command will set an internal LT51 <Config>uration to <Value>. The
following Configurations and their values can be set with this command:
Configuration
<Config>
<Value>
MEASMODE
0x00
0x20 = LEVSPCTM
0x21 = PSD
0x23 = IPNOISE
0x26 = TDR
0x28 = OSB
0x30 = NEXT / Loss
0x31 = FEXT
0x32 = ILOSS
0x34 = RLOSS
0x38 = LCL
0x41 = VOLTAGE
0x43 = TRACETONE
0x47 = R & C
0x73 = MAGZ
TERMINALS
0x02
0x00 = a-b
0x01 = a-g
0x02 = b-g
RXRANGE
0x03
0x00 = +30 dB
0x01 = +20 dB
0x02 = +10 dB
0x03 = 0 dB
0x04 = -10 dB
0x05 = -20 dB
0x06 = -30 dB
BW
0x04
0x00 = Max Span to
0x0A = Min Span
SWEEPING
0x05
0x00 = OFF
0x01 = ON
ZRTX
0x06
0x00 = 50
0x01 = 75
0x02 = 600
ZTX
0x07
0x00 = 50
0x01 = 75
0x02 = 600
INPUT
0x08
0x00 = Terminated
0x01 = HiZ
Summary of Contents for UMDT51A
Page 34: ...Testing PLC Systems LT51 User Manual 22...
Page 50: ......
Page 98: ......
Page 103: ......
Page 104: ......