TIG AC - Pulsed

The Pulse function is available in TIG AC - Easy and TIG AC - Standard. The pulse frequency is adjustable from 0.1 Hz to 10 Hz.

TIG SPOT DC or AC

The " SPOT" mode allows the pre-assembly of parts by tacking. The tacking time adjustment allows a better reproducibility and the realisation of 

non-oxidised tack. As default, when the " SPOT " mode is selected, the start and the end of the welding is done at the trigger. However, the " F(Hz) " 

button and the main encoder allow the user to refine this time. The time in this "SPOT" tacking mode is adjustable by 0.1 sec. at 60 sec. in steps of 

0.1 sec. The ignition is then done with the trigger. To return to an undefined spot time, simply select "0.0s".

JOBS MANAGEMENT

The current settings are automatically saved and loaded at start up. In addition to the current settings, it is possible to save and recall so-called "JOB" 

configurations. The " JOB " button is used to save, recall or delete a configuration. 50 Jobs can be stored per welding process.

• 

Job Recall

- Apart from not being in the welding process, the recall of a job does not require any particular initial condition,

- Press the " JOB " button briefly (not more than 2 sec.),

- " OUT " appears on the HMI display,

- With the incremental encoder, select a job number. Only the numbers associated with existing jobs appear on the display If no job is stored, the 

HMI displays "- - - -".

- Once the job number has been selected, press the "JOB" button to confirm the configuration. The job number then flickers on the display, indicating 

that the job has been loaded. The number continues to flicker until another parameter is changed or until the torch trigger is pressed to start the 

welding cycle.

 Job deletion

- Press the "JOB" button briefly (not more than 2 sec.),

- "OUT" appears on the HMI display,

- With the incremental encoder, select a job number. Only numbers associated with existing jobs can be displayed,

- Press successively 3 times on the " JOB " button. The selected job is now deleted and the power source displays the welding current again.

• 

Job creation

- Adjust all desired welding parameters,

- Press and hold the " JOB " button for more than 3 seconds,

- The display shows "IN",

- Select a job number using the incremental encoder. Only numbers that are not already assigned to a previously saved job can be selected and are 

shown on the display,

- Once the job number has been chosen, press the "JOB" button to validate and save it under the selected number,

- The job number then remains displayed, indicating that the save action has been completed. The number continues to be displayed until another 

button or the torch trigger is activated.

Note: If all numbers are already assigned to saved jobs, the HMI displays "Full".

Precisions for a job reminder in TIG AC: The special feature of a job reminder in TIG AC is the display of the parameters related to the "AC" functions. 

When a job configuring the station in "AC" is called up, the HMI then displays successively the values of the welding current (in A), the balance (in %) 

and the frequency (in Hz) following a repetitive cycle. This cycle lasts until the torch trigger is pulled to start a welding cycle.

COMPATIBLE TORCHES AND TRIGGER TYPES

L

DB

P

L

DB

P

L

DB

P

For the 1 button torch, the button is called "main button".

For the 2 buttons torch, the first button is called "main button" and the second button is called "secondary button".

 

 

2T MODE

t

t

t

t

t

t

T2

T1

Main button

T3

T1

Main button

T2

T4

T3

T1

Main button

T2

T4

Secondary button

or

>0.5s

<0.5s

<0.5s

T1: The main button is pressed, the welding cycle starts (PreGas, I_Start, 

UpSlope and welding).

T2: The main button is released, the welding cycle is stopped (DownSlope, 

I_Stop, PostGas).

For the double button torch and in 2T mode only, the secondary button 

works like the main button.

26

EN

Translation of the original instructions

PROTIG 201 AC/DC - 201L AC/DC

Summary of Contents for PROTIG 201 AC/DC

Page 1: ...4 09 2020 FR 2 15 97 104 EN 16 28 97 104 PROTIG 201 AC DC 201L AC DC DE 29 41 97 104 ES 42 54 97 104 RU 55 68 97 104 www gys fr Find more languages of user manuals on our website IT 83 96 97 104 NL 69...

Page 2: ...eyes during cleaning operations Contact lenses are prohibited during use It may be necessary to install fireproof welding curtains to protect the area against arc rays weld spatter and sparks Inform t...

Page 3: ...e that the cable cross section is adequate with the usage extensions and welding cables Always wear dry clothes which are in good condition in order to be isolated from the welding circuit Wear insula...

Page 4: ...tween the conduct and the casing of the welding current source b Maintenance of the arc welding equipment The arc welding machine should be subject to a routine maintenance check according to the reco...

Page 5: ...Flexible Voltage feature and needs to be powered by an earthed electrical installation between 110V and 240V 50 60Hz For intensive use at 110 V replace the original plug with a 32 A plug protected by...

Page 6: ...on the control board red box on diagram below n 2 4 Turn the switch located on this control card ON The red LED switches off 5 The VRD function is activated 6 Screw the power source cover back on 7 O...

Page 7: ...ot modes AC DC Choose between TIG DC TIG AC and TIG AC Easy AC Select the parameter to be adjusted between Frequency and Balance A V display selection By default the welding current is displayed on th...

Page 8: ...e current setting It is also possible to press another key related to another parameter to adjust it The buttons concerned are the BP1 to BP5 and the adjustment BP in AC If no action is performed on t...

Page 9: ...setting by pressing the A V button ISO Set the welding end current it is set as a percentage of the welding current setpoint It can be adjusted between 10 and 200 Validate the entered setting by press...

Page 10: ...rch trigger the arc starts without contact using High Frequency impulsions 3 The initial welding current flows the weld will be continues according to the welding cycle 1 Position the torch nozzle and...

Page 11: ...37 3 2 mm 60 A 180 A 43 4 0 mm 75 A 200 A 50 With this mode the frequency value is related to the welding current value as follows Current A Frequency Hz 10 40 117 41 90 100 91 140 79 141 170 70 171 2...

Page 12: ...ay With the incremental encoder select a job number Only numbers associated with existing jobs can be displayed Press successively 3 times on the JOB button The selected job is now deleted and the pow...

Page 13: ...s from I welding to I cold The secondary button is released the current switches from I cold to I welding T3 A long press on the main button 0 5 sec the cycle switches to DownSlope and stops in the I_...

Page 14: ...of the current from the minimum current to 100 of the set intensity In TIG the welding machine only operates in 2T mode The upslope and downslope are not automatically managed by the current source a...

Page 15: ...tion cable pedal connector Kabel Anschluss f r Fernsteuerung Cable conector pedal Kabel aansluiting pedaal Fasciocavo connettore pedale 71513 5 lectrovanne Solenoid valve Magnetventil Electrov lvula M...

Page 16: ...Anschluss Conexi n gas Gasaansluiting Connessione gas 55090 19 Connecteur torche faisceau Torch connection Connection cable Brenner Anschluss Zwischenschlauchpaket Conector antorcha cable de uni n Aan...

Page 17: ...E SCHEMA SCEMA ELETTRICO 21464 63662 63678 51461 96130 51461 71542 M 51021 71873 71513 97799C 97798C 97801C 97155C 97797C 5 4 7 2 97796C 51978 201 AC DC 21464 63662 63678 51461 96130 51461 71542 M 510...

Page 18: ...Grado de protecci n Beschermingsklasse Grado di protezione IP21 Dimensions Lxlxh Dimensions Lxlxh Abmessung LxBxH Dimensiones Lxlxh Afmetingen Lxlxh Dimensioni Lxlxh 24 x 41 x 36 cm Poids Weight Gewi...

Page 19: ...ions Lxlxh Abmessung LxBxH Dimensiones Lxlxh Afmetingen Lxlxh Dimensioni Lxlxh 24 x 43 x 50 cm Poids Weight Gewicht Peso Gewicht Peso 20 5 Kg Les facteurs de marche sont r alis s selon la norme EN6097...

Page 20: ...nsion assign e d alimentation Rated power supply voltage Netzspannung Tensi n de la red Netspanning Tensione nominale di alimentazione I1max Courant d alimentation assign maximal valeur efficace Maxim...

Page 21: ...rf gbar siehe Titelseite Equipo conforme a los requisitos brit nicos La Declaraci n de Conformidad Brit nica est disponible en nuestra p gina web v ase la portada Materiaal conform aan de Britse eisen...

Page 22: ...i sicurezza costituito dalla presa elettrica in coordinazione con l installazione elettrica domestica L utente deve assicurarsi dell acces sibilit della presa Refroidissement Cooling K hlung Refrigera...

Reviews: