21
EXAGON 400 CC/CV
EN
MODE SELECTION AND SETTINGS
Press the button
several times until the LED light switches on below the
symbol
.
Adjust the arc voltage using the main knob
, the voltage setpoint is is indi-
cated on the left side display.
• 36V to 45V for a 6.35 mm electrode.
• 39V to 45V for a 8 mm electrode.
Rutile
0
+9
-9
Basic
ARC FORCE
INDUCTANCE
Cellulosic
6013
7018
6010
MMA
press 3 s
MIG
TIG
setup
memory
Gouging
CV
MODE
MADE IN FR ANCE
A
V
VRD
press 3s
press 3s
The grey areas are not useful for this mode.
DISPLAY CURRENT/VOLTAGE DURING WELDING
During welding, the machine measures and displays the welding current and voltage. After the weld, the average current and voltage values are
displayed during 30 seconds, as soon as a knob or a button is pressed, the welding parameters are displayed.
SAVE AND LOAD WELDING SETTINGS
The current settings are automatically saved and loaded at start up.
On top of the current settings, it is also possible to save and load 50 settings per each mode.
The memory recalls :
- Primary setting
- Secondary setting (MMA, CV)
- Secondary settings (MMA)
Save new settings :
- Maintain buttons
and
during 3 seconds.
appears, release the buttons.
- Turn one of the two knobs
. Validate by pressing the button
.
- The display indicates a memory set (01 to 50) while blinking.
- Turn the knob to select the memory set in which the desired settings will be saved. Validate by pressing the button
.
- The settings are saved / the menu exit is instantaneous.
Load existing settings :
- Maintain the buttons
and
during 3 seconds.
appears, release the buttons.
- Turn one of the two knobs to display
. Validate by pressing the button
.
- The display indicates a memory set (01 to 50) while blinking.
- Turn one of the two knobs to select the memory set containing the desired settings to load. Validate by pressing the button
.
The settings are loaded / the menu exit is instantaneous.
REMOTE CONTROL
CONNECTIONS AND RECOMMENDATIONS
The remote control works in all modes (except in semi-auto mode with a workshop wire feeder where all controls are on the wire feeder).
The remote control acts on the primary settings of the current process (MMA and TIG, voltage and gouging).
Connections :
1- Plug the remote control on the machine’s front.
2- The machine will detect the remote control automatically and open a selection menu:
Foot pedal selection.
Remote control with potentiometer selection.
The remote ontrol type selection is done with the two knobs, the validation is done with the button
.
The LED (FIG-2, n°14) switches on.
It is possible to activate / deactivate the remote control without having to physically unplug the remote control. Press the button
, for 3
seconds, the LED (FIG-2, n°14) indicates the state of the remote control (LED on = remote control on).
Operations :
• Manual remote control (GYS product ref. 045675).
The manual remote control can adjust :
- the current from 50% to 100% of the set intensity using the main knob. The displayed current setpoint matches the potentiometer position. The