21
GYSFLASH 30-24 HF
EN
1
Battery analysis
TRACTION CHARGE
2
Recovering damaged elements from an extended deep discharge
3
Sulphated battery test
4
Sulphated battery recovery
5
Checking the battery recovery
6
Battery charged to 80%
7
Battery charged to 90%
8
Battery cells refresh
9
Cells break time
10
Battery cells equalization
11
Battery charged to 100% (charge resumption after 48h)
PROTECTIONS
This device is protected against short-circuits and polarity inversions. It has an anti-spark feature which prevents sparks whilst
connecting this charger to the battery. This charger will not deliver current if there is no battery detected (no voltage in the clamps).
The charger is fitted with an internal 40A fuse (ref. 054646), to protect against misuse.
TROUBLESHOOTING
TROUBLESHOOTING
CAUSES
REMEDIES
1
Screen flashing :
« #error (+)<-->(-) »
+ alarm beep
The polarity has been reversed on the clamps
Connect the red clamp to the (+) and the black clamp to the (-) of the battery.
2
Screen flashing :
« #error U>Umax »
+ alarm beep
Battery voltage too high
Charger not suitable.
3
Screen flashing :
« #battery error »
+ alarm beep
Battery in short-circuit or damaged
Change the battery.
Battery not connected or clamps in short-circuit
Check clamps connection.
Error on the battery voltage selection
Charger not suitable.
4
Screen flashing :
« >30A »
+ alarm beep
Consumption exceeds the output of the charger
Turn off electrical consumers to reduce power demand
5
The charger delivers a high current
(greater than 10A) before the dia-
gnostic tool has been activated.
Several consumers are active on the vehicle
The charger works to specification. Turn off consumers to check the battery is
not too discharged (see cause n°2).
Battery discharged
Battery deeply discharged, the charger delivers current to charge it. Wait until
the output current is below 10A to start the diagnostic.
6
Displays for 1s :
« no battery »
+ alarm beep
«Showroom mode is working on « no battery »
Showroom without battery : the charger operating normally.
To deactivate the «no battery» function, press the «START/STOP» key, and then
press the «START/STOP» key again to start the Showroom mode with battery.
7
The device is locked in Showroom
mode
Lock Showroom active
The charger works to specification.
See configuration menu to deactivate the function.
8
Screen displays :
« #error T(°C) »
+ alarm beep
Faulty fan
Contact your distributor.
Sun exposure
Do not leave the device exposed to sunlight.
Leave the device ON until the fault disappears. (The alarm beep can be stopped
Possibility to stop the alarm beep by pressing the START/STOP key).
9
Screen displays :
« #error IHM »
+ alarm beep
Electronic fault
Contact your distributor.
10
Screen displays :
« #error fuse
»
+ alarm beep
Mishandling
Internal fuse must be changed by a qualified person
(ref: 054646: 40A).
11
The device does not display
anything
Input fuse faulty
Input fuse must be changed by a qualified person
(temporised fuse 10A 5x20 ref. 054530).
Faulty electrical network
Check the voltage of the electrical network is between 180V and 260V.